Page 4<br />

<strong>Australian</strong> <strong>Building</strong> <strong>Codes</strong> <strong>Board</strong><br />

Reference<br />

Table E1.6<br />

Changes and Commentary<br />

As a consequence of exempting a Class 2 or 3 building or Class 4 part<br />

of a building from compliance with E1.4, Table E1.6 has been amended<br />

to require fire extinguishers to be installed to cover Class A fire risks<br />

associated with a Class 2 or 3 building or Class 4 part of a building.<br />

Specification Clause 6 has been restructured and amended to require sprinkler alarm<br />

E1.5 Clause valves and main stop valves to be easily identified and accessed by the<br />

6 fire brigade from a public road or open space.<br />

Table E2.2a<br />

A new note has been inserted to clarify that zone smoke control<br />

requirements do not apply to a single fire compartment in a Class 5, 6,<br />

7b, 8 or 9b building in an otherwise residential building.<br />

E4.8 The provision has been amended to permit the use of photoluminescent<br />

exit signs.<br />

Specification A new Specification has been inserted to detail specific requirements for<br />

E4.8 photoluminescent exit signs.<br />

Section F<br />

F1.1 The provision has been restructured and amended as a consequence of<br />

including requirements that quantify the amount of overflow that must be<br />

accommodated by an eaves gutter system.<br />

Table F1.1a<br />

Table F1.1b<br />

A new Table has been inserted to include requirements that quantify the<br />

amount of overflow that must be accommodated by an eaves gutter<br />

system.<br />

A new Table has been inserted to detail different types of measures that<br />

can be used in an eaves gutter system to accommodate different<br />

overflow amounts.<br />

F1.11 The provision has been restructured and amended to clarify that a floor<br />

waste, as well as grading of the floor, is mandatory in the situations<br />

described.<br />

FF2.2<br />

FP2.2<br />

FO5(d)<br />

FF5.1<br />

FP5.7<br />

The Functional Statement has been amended to recognise the need for<br />

a building to be provided with adequate means for the disposal of waste<br />

water.<br />

The Performance Requirement has been amended to recognise the<br />

need for a building to be provided with adequate means for the disposal<br />

of waste water.<br />

A new sub-clause (d) has been inserted to require consideration of<br />

sound transmission from outside the building to sole-occupancy units in<br />

a Class 2 building.<br />

PUBLIC COMMENT DRAFT<br />

The Functional Statement has been restructured and amended to require<br />

consideration of sound transmission from outside the building to a soleoccupancy<br />

unit in a Class 2 building.<br />

A new Performance Requirement has been inserted to require sound<br />

insulation to the external part of the building to minimise sound<br />

transmission from road and rail noise to sole-occupancy units in a Class<br />

2 building.<br />

NCC2014 Volume One