Page 4<br />

<strong>Australian</strong> <strong>Building</strong> <strong>Codes</strong> <strong>Board</strong><br />

PART F1<br />

DAMP AND WEATHERPROOFING<br />

Deemed-to-Satisfy Provisions<br />

F1.0 Deemed-to-Satisfy Provisions<br />

(a)<br />

Performance Requirement FP1.4, for the prevention of the penetration of water<br />

through external walls, must be complied with.<br />

There are no Deemed-to-Satisfy Provisions for this Performance Requirement in<br />

respect of external walls.<br />

SA F1.0(b)<br />

(b)<br />

(c)<br />

Where a <strong>Building</strong> Solution is proposed to comply with the Deemed-to-Satisfy<br />

Provisions, Performance RequirementsFP1.1 to FP1.3 and FP1.5 to FP1.7 are<br />

satisfied by complying with F1.1 to F1.13.<br />

Where a <strong>Building</strong> Solution is proposed as an Alternative Solution to the Deemed-to-<br />

Satisfy Provisions of F1.1 to F1.13, the relevant Performance Requirements must<br />

be determined in accordance with A0.10.<br />

F1.1 Stormwater drainage<br />

Stormwater drainage must— comply with AS/NZS 3500.3.<br />

(a)<br />

comply with AS/NZS 3500.3; and<br />

(b) where eaves gutters are installed, be designed to remove rainwater falling at a 5<br />

minute duration rainfall intensity for a—<br />

(i)<br />

(ii)<br />

100 year average recurrence interval; or<br />

20 year average recurrence interval, if not less than one overflow measure<br />

per downpipe is installed in accordance with Table F1.1b to remove the<br />

appropriate overflow volume in Table F1.1a.<br />

Table F1.1a DESIGN OVERFLOW VOLUME<br />

Design overflow Roof catchment area per downpipe (m 2 )<br />

rainfall intensity<br />

30 40 50 60 70<br />

(mm/h) (see Note 1)<br />

Design overflow volume per downpipe (L/s)<br />

40 0.33 0.44 0.56 0.67 0.78<br />

PUBLIC COMMENT DRAFT<br />

50 0.42 0.56 0.69 0.83 0.97<br />

60 0.50 0.67 0.83 1.00 1.17<br />

70 0.58 0.78 0.97 1.17 1.36<br />

80 0.67 0.89 1.11 1.33 1.56<br />

90 0.75 1.00 1.25 1.50 1.75<br />

F1.0<br />

NCC2014 Volume One