PDF | 8 MB - Australian Building Codes Board
PDF | 8 MB - Australian Building Codes Board
PDF | 8 MB - Australian Building Codes Board
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Page 8<br />
<strong>Australian</strong> <strong>Building</strong> <strong>Codes</strong> <strong>Board</strong><br />
Deemed-to-Satisfy Provisions<br />
External Total area of Designated sound exposure category<br />
part windows<br />
serving the<br />
room as a<br />
percentage of 1 2 3 4 5<br />
the floor area of<br />
the room<br />
Floor N/A 50 50 50 50 50<br />
Roof N/A 45 45 45 45 45<br />
Door N/A 30 30 35 35 40<br />
Windows<br />
in<br />
bedrooms<br />
Not more than<br />
20%<br />
25 28 31 34 37<br />
More than 20%<br />
but not more 28 31 34 37 40<br />
than 40%<br />
More than 40%<br />
but not more 31 34 37 40<br />
than 60%<br />
More than 60%<br />
but not more 34 37 40<br />
than 80%<br />
More than 80%<br />
but not more 37 40<br />
than 100%<br />
More than 100%<br />
but not more 40<br />
than 120%<br />
More than 120%<br />
PUBLIC COMMENT DRAFT<br />
Not Permitted<br />
F5.8<br />
NCC2014 Volume One