<strong>Australian</strong> <strong>Building</strong> <strong>Codes</strong> <strong>Board</strong> Page 11<br />
Deemed-to-Satisfy Provisions<br />
R w +<br />
L n,w + R C w<br />
tr C I (not (not<br />
Description (not Construction<br />
more less<br />
less<br />
than) than)<br />
than)<br />
(a)<br />
(b)<br />
(c)<br />
28 mm metal furring<br />
channels and isolation<br />
mounts fixed to underside of<br />
slab, at 600 mm centres; and<br />
30 mm thick glass or mineral<br />
wool insulation with a density<br />
of 11 kg/m 3 or 30 mm thick<br />
polyester insulation with a<br />
density of 14 kg/m 3 ,<br />
positioned between furring<br />
channels; and<br />
one layer of 10 mm<br />
plasterboard fixed to furring<br />
channels.<br />
200 mm thick concrete slab with<br />
carpet on underlay.<br />
200 mm thick concrete slab.<br />
100 mm thick concrete slab.<br />
50 - 50<br />
50 62 50<br />
50 - 50<br />
45 - 45<br />
PUBLIC COMMENT DRAFT<br />
NCC2014 Volume One Spec F5.2 – 2.