Table J2.4a ENERGY INDEX<br />

Application<br />

Energy<br />

index<br />

option<br />

<strong>Australian</strong> <strong>Building</strong> <strong>Codes</strong> <strong>Board</strong> Page 3<br />

Deemed-to-Satisfy Provisions<br />

Climate zone<br />

1 2 3 4 5 6 7 8<br />

Glazing in a A 0.067 0.132 0.091 0.086 0.092 0.090 0.059 0.027<br />

Class 3 building<br />

and a Class 9c<br />

Not<br />

aged care B 0.060 0.124 0.078 0.063 0.071 0.061 0.037<br />

applicable<br />

building<br />

Glazing in a A 0.080 0.158 0.109 0.103 0.110 0.108 0.071 0.032<br />

Class 9c aged<br />

Not<br />

care building B 0.072 0.149 0.094 0.076 0.085 0.073 0.044 applicable<br />

Display glazing A 0.180 0.217 0.221 0.227 0.257 0.220 0.170 0.046<br />

in a shop or<br />

Not<br />

showroom B 0.173 0.209 0.208 0.204 0.236 0.191 0.148 applicable<br />

Glazing in other A 0.130 0.181 0.172 0.142 0.175 0.116 0.083 0.023<br />

than, a Class 3<br />

building, a<br />

Class 9c aged<br />

care building or<br />

display glazing in<br />

B<br />

Not<br />

0.123 0.173 0.159 0.113 0.145 0.082 0.058 applicable<br />

a shop or<br />

showroom<br />

Note: Option A applies to all glazing other than where compliance with Option B is<br />

required by Table J1.5a.<br />

(c)<br />

The aggregate air-conditioning energy value must be calculated by adding the airconditioning<br />

energy value through each glazing element in accordance with the<br />

following formula:<br />

A 1 [SHGC 1 (C A xS H1 +C B xS C1 )+C C xU 1 ] + A 2 [SHGC 2 (C A xS H2 +C B xS C2 )+C C xU 2 ] + ...<br />

where—<br />

A 1, 2, etc = the area of each glazing element; and<br />

C A, B and C = the energy constants A, B and C for the specific orientation<br />

from Table J2.4b; and<br />

SHGC 1, 2, etc = the Total System SHGC of each glazing element; and<br />

PUBLIC COMMENT DRAFT<br />

S H1, 2, etc = the heating shading multiplier for each glazing element<br />

obtained from Table J2.4c; and<br />

S C1, 2, etc = the cooling shading multiplier for each glazing element<br />

obtained from Table J2.4d; and<br />

U 1, 2, etc = the Total System U-Value of each glazing element.<br />

(d)<br />

For the purposes of (c)—, where the air-conditioning energy value of a glazing<br />

NCC2014 Volume One J2.4