SCA1666<br />

The shock spectrum shown in figure 5-9 represents the maximum expected<br />

shock environment for the spacecraft adapter with a diameter of<br />

1666 mm and a Marmon clamp separation system.<br />

The shock spectrum corresponds to a tension of 30 kN in the spacecraft<br />

adapter clampband and is defined for a location 12.7 cm (5 in) from the<br />

separation plane on the spacecraft side of the interface.<br />

The strength capability of the SCA1666 spacecraft adapter with this<br />

clampband tension is given in section 6.1.<br />

10000<br />

Shock spectra<br />

•Q=10<br />

• Shock at 5 inches on<br />

SC side of interface<br />

1000<br />

Acceleration, g<br />

100<br />

Freq, Hz Level, g<br />

100 150<br />

800 3000<br />

3000 3000<br />

6000 3500<br />

9000 3500<br />

10000 4000<br />

10<br />

100 1000 10000<br />

Frequency, Hz<br />

Figure 5-9. Separation Shock for SCA1666 Spacecraft Adapter<br />

265807J3-064R3<br />

5-10 D688-10009-1 REV B