Safety & Health in the Stone Crushing Industry - Occupational ...
Safety & Health in the Stone Crushing Industry - Occupational ...
Safety & Health in the Stone Crushing Industry - Occupational ...
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
68<br />
2.3<br />
2.4<br />
2.5<br />
2.6<br />
2.7<br />
2.8<br />
2.10<br />
2.11<br />
2.12<br />
2.13<br />
2.14<br />
2.15<br />
2.16<br />
Are all cable trenches covered properly and<br />
cables <strong>in</strong> cable trays secured properly?<br />
Are all connections and electrical devices<br />
grounded?<br />
Are <strong>the</strong>re fire ext<strong>in</strong>guishers and rubber mats<br />
close to important electrical <strong>in</strong>stallations?<br />
Are <strong>the</strong>re bare and raw wires <strong>in</strong>serted directly<br />
<strong>in</strong>to sockets?<br />
Are MCB/ELCBs provided for protect<strong>in</strong>g <strong>the</strong><br />
operator from electrical hazards?<br />
Is <strong>the</strong> ma<strong>in</strong> switch box <strong>in</strong> good condition,<br />
protected from wea<strong>the</strong>r, and provided with an<br />
ELCB?<br />
Are all distribution boxes marked legibly <strong>in</strong> an<br />
understandable language mark<strong>in</strong>g <strong>the</strong> feed<strong>in</strong>g<br />
po<strong>in</strong>t, voltage, and identification number?<br />
Are electrical conductors such as cables of<br />
sufficient size and load carry<strong>in</strong>g capacity?<br />
Are <strong>the</strong>re <strong>in</strong>terlocks and a lockout-tagout<br />
system <strong>in</strong> place for electrical equipment dur<strong>in</strong>g<br />
repair?<br />
Do workers who do electrical work wear <strong>the</strong><br />
necessary PPE, like shoes and gloves and are<br />
equipped with approved rubber mats?<br />
Dur<strong>in</strong>g electrical ma<strong>in</strong>tenance, a lockout/tagout<br />
system is <strong>the</strong> mandatory and workers are<br />
tra<strong>in</strong>ed to follow <strong>the</strong>se <strong>in</strong>structions<br />
The transformer where <strong>the</strong> <strong>in</strong>com<strong>in</strong>g electricity<br />
supply is received is isolated and fenced off; its<br />
compound is clean from vegetation to prevent<br />
fire. The transformers are positioned at least<br />
2.50 meters above ground level.<br />
Electrical cables are laid <strong>in</strong>to <strong>the</strong> ground <strong>in</strong><br />
shock-proof material. Cables should be run <strong>in</strong><br />
extra plastic conduits<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
MAXIMUM POSSIBLE SCORE: 26<br />
ACHIEVED SCORE: ………………..<br />
Notes: