Mounting and Temperature Conditions<br />
Install the unit vertically to within +/-10 °.<br />
Do not place it close to heating elements.<br />
Leave sufficient free space to ensure that the air required for cooling purposes can circulate from the bottom<br />
to the top of the unit.<br />
ATV<strong>38</strong>HU18N4 to D23N4<br />
³ 50<br />
Free space in front of unit: 10 mm minimum.<br />
ENGLISH<br />
³ d ³ d<br />
³ 50<br />
ATV<strong>38</strong>HU18N4 to U90N4:<br />
From - 10 °C to 40 °C: d ≥ 50 mm: no special precautions.<br />
d = 0: remove the protective blanking cover from the top of the <strong>drive</strong> as shown overleaf<br />
(the degree of protection is then IP 20).<br />
From 40 °C to 50 °C:<br />
d ≥ 50 mm: remove the protective blanking cover from the top of the <strong>drive</strong> as shown<br />
overleaf (the degree of protection is then IP 20).<br />
d = 0: add control ventilation kit VW3A5882• (see ATV<strong>38</strong> catalogue).<br />
From 50 °C to 60 °C:<br />
d ≥ 50 mm: add control ventilation kit VW3A5882• (see ATV<strong>38</strong> catalogue).<br />
Derate the operating current by 2.2% per °C over 50 °C.<br />
ATV<strong>38</strong>HD12N4 to D23N4:<br />
From - 10 °C to 40 °C: d ≥ 50 mm: no special precautions.<br />
d = 0: remove the protective blanking cover from the top of the <strong>drive</strong> as shown overleaf<br />
(the degree of protection is then IP 20).<br />
From 40 °C to 50 °C:<br />
d ≥ 50 mm: remove the protective blanking cover from the top of the <strong>drive</strong> as shown<br />
overleaf (the degree of protection is then IP 20).<br />
Derate the current by 2.2% per °C over 40 °C.<br />
d = 0: add control ventilation kit VW3A5882 (see ATV<strong>38</strong> catalogue). Derate the current<br />
by 2.2% per °C over 40 °C.<br />
75