Mounting in a Wall-fixing or Floor-standing<br />

Enclosure<br />

Observe the mounting recommendations on the previous page.<br />

To ensure proper air circulation in the <strong>drive</strong>:<br />

- Fit ventilation grilles<br />

- Ensure that ventilation is adequate: if not, install<br />

forced ventilation with a filter<br />

- Use special IP 54 filters<br />

Dust and damp proof metal wall-fixing or floor-standing<br />

enclosure (IP 54 degree of protection)<br />

The <strong>drive</strong> must be mounted in a dust and damp proof casing in certain environmental conditions: dust,<br />

corrosive gases, high humidity with risk of condensation and dripping water, splashing liquid, etc.<br />

ENGLISH<br />

To avoid hot spots in the <strong>drive</strong>, add a fan to circulate the air inside the enclosure, reference VW3A5882• (see<br />

ATV<strong>38</strong> catalogue).<br />

This enables the <strong>drive</strong> to be used in an enclosure where the maximum internal temperature can reach 60 °C.<br />

Calculating the size of the enclosure<br />

Maximum thermal resistance Rth (°C/W) :<br />

Rth =<br />

θ° - θ°e<br />

P<br />

θ° = maximum temperature inside enclosure in °C<br />

θ°e = maximum external temperature in °C<br />

P = total power dissipated in the enclosure in W<br />

Power dissipated by the <strong>drive</strong>: see section Selecting a <strong>drive</strong>.<br />

Add the power dissipated by the other equipment components.<br />

Useful heat dissipation surface of enclosure S (m 2 ):<br />

(sides + top + front panel if wall-mounted)<br />

S =<br />

K<br />

Rth<br />

K = enclosure thermal resistance per m 2<br />

For metal enclosure:<br />

K = 0.12 with internal fan<br />

K = 0.15 without fan<br />

Caution: Do not use insulated enclosures, as they have a poor level of conductivity.<br />