5.0 Energy Management services:<br />

Firm should be doing online energy audit based on the continuous reports being<br />

generated through the system with the help of energy auditor and submitting reports on<br />

quarterly basis for two years covering following points<br />

1. Previous 3 month analysis of energy management reports generated from web based<br />

energy management system<br />

2. Running hours to be decided based on average requirement.<br />

3. Suggestion for any addition/ modification in alert and alarm requirement for <strong>Railway</strong>s.<br />

4. Suggesting for changes in auto control facility for <strong>Railway</strong>s.<br />

5. Submitting printout of one original and 2 duplicate copy<br />

6.0 Inspection of material<br />

6.1 For inspecting the major/high value items, <strong>Railway</strong>’s representative will visit to<br />

manufacturer’s premises to conduct the test. Contractor shall provide all necessary<br />

assistance in carrying out below mentioned test and inspection at his own cost.<br />

A. Software features:-<br />

a) Web based report generation of all the function requirement of software as per<br />

specification<br />

b) Rule based control in form of SMS/ Email/ Alarm/ ON/ OFF action.<br />

c) Web/ SMS based control of pumps<br />

d) SMS based feedback in case alert or alarm generation to assigned person of <strong>Railway</strong>s<br />

in case<br />

1. On-Off<br />

2. Door open<br />

3. No Input supply<br />

4. Light failed to operate (on/off)<br />

5. Crossing bench mark figure of each parameter<br />

e) Dashboard view feature<br />

f) Group data report and modification<br />

g) Controlling of light minimum from 5 KMS distance and<br />

i) Access possibility minimum from 5 places.<br />

B. Hardware features:-<br />

1. High voltage protection tripping<br />

2. Protection against short circuit protection<br />

3. Protection against single phase phasing.<br />

4. Protection against neutral missing, phase to phase shorting<br />