63%<br />

Back-Wall Scan<br />

74%<br />

FBH scan<br />

58%<br />

40%<br />

64%<br />

60%<br />

59%<br />

57%<br />

42%<br />

61%<br />

68%<br />

47%<br />

33%<br />

37%<br />

35%<br />

37%<br />

57%<br />

56%<br />

64%<br />

71%<br />

68%<br />

55%<br />

69%<br />

66%<br />

64%<br />

48%<br />

49%<br />

46%<br />

38%<br />

66%<br />

66%<br />

36%<br />

(a)<br />

Amplitude (%FSH)<br />

(c)<br />

Comparison of Normalized<br />

BW and FBH variations<br />

(5-MHz Phased Array; Focused on Backwall; Trial 1)<br />

80<br />

70<br />

60<br />

50<br />

40<br />

30<br />

20<br />

10<br />

FBH PA-foc_at_back<br />

Average <strong>for</strong> all sites = 50%<br />

0<br />

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14<br />

Measurement Site<br />

BW PA-foc_at_back<br />

FBH Amplitude (% FSH)<br />

(b)<br />

Correlation Between Norm'ed<br />

BW and FBH variations<br />

(5-MHz Phased Array; Focused on Backwall; Trial 1)<br />

80<br />

70<br />

y = 1.005x<br />

R 2 60<br />

= 0.7744<br />

50<br />

40<br />

30<br />

(d)<br />

Trendline thru origin<br />

20<br />

10<br />

0<br />

0 10 20 30 40 50 60 70 80 90 100<br />

BW Amplitude (% FSH)<br />

Figure 4. Measurements on a Ti 6-4 billet segment using a 5-MHz phased-array transducer<br />

focused near the billet back wall, following the style of Figure 1. Beam diameters (-6 dB) near the<br />

back wall are approximately 200 mils x 380 mils (axial x hoop).<br />

<strong>Evaluation</strong> of Transducers<br />

The two 7.5 MHzF/10 aperture elliptical transducers were evaluated in more detail than the<br />

preliminary evaluation reported in the previous quarterly. Frequency measurements were made<br />

using the echoes from #2FBH targets in 10” diameter calibration standards. Tables 1 and 2<br />

compares these frequency measurements with those supplied by the manufacturer, which had<br />

been measured on a flat brass target, located at the near focal point, in water.<br />

In order to assess the per<strong>for</strong>mance relative to the #1FBH sensitivity program goal, a number of<br />

scans were made using the 10 inch diameter Ti 64 ETC standards, which contain targets of various<br />

diameters down to 0.4 mm (1/64 inch). These scans were done as closely as possible to<br />

production inspection conditions, with the exceptions that the scan index was reduced to 0.01” in<br />

order to capture the peak signals, and the gate length was reduced where necessary to avoid back<br />

surface signals in the gate. For the zone 2 transducer, targets at 0.9”, 1.35” and 1.8” (start, center,<br />

Quarterly Report – January 1, 2002 –March 31, 2002<br />

print date/time: 6/6/2002 - 8:39 AM – Page 28