Engine Titanium Consortium - Center for Nondestructive Evaluation ...
Engine Titanium Consortium - Center for Nondestructive Evaluation ...
Engine Titanium Consortium - Center for Nondestructive Evaluation ...
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
63%<br />
Back-Wall Scan<br />
74%<br />
FBH scan<br />
58%<br />
40%<br />
64%<br />
60%<br />
59%<br />
57%<br />
42%<br />
61%<br />
68%<br />
47%<br />
33%<br />
37%<br />
35%<br />
37%<br />
57%<br />
56%<br />
64%<br />
71%<br />
68%<br />
55%<br />
69%<br />
66%<br />
64%<br />
48%<br />
49%<br />
46%<br />
38%<br />
66%<br />
66%<br />
36%<br />
(a)<br />
Amplitude (%FSH)<br />
(c)<br />
Comparison of Normalized<br />
BW and FBH variations<br />
(5-MHz Phased Array; Focused on Backwall; Trial 1)<br />
80<br />
70<br />
60<br />
50<br />
40<br />
30<br />
20<br />
10<br />
FBH PA-foc_at_back<br />
Average <strong>for</strong> all sites = 50%<br />
0<br />
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14<br />
Measurement Site<br />
BW PA-foc_at_back<br />
FBH Amplitude (% FSH)<br />
(b)<br />
Correlation Between Norm'ed<br />
BW and FBH variations<br />
(5-MHz Phased Array; Focused on Backwall; Trial 1)<br />
80<br />
70<br />
y = 1.005x<br />
R 2 60<br />
= 0.7744<br />
50<br />
40<br />
30<br />
(d)<br />
Trendline thru origin<br />
20<br />
10<br />
0<br />
0 10 20 30 40 50 60 70 80 90 100<br />
BW Amplitude (% FSH)<br />
Figure 4. Measurements on a Ti 6-4 billet segment using a 5-MHz phased-array transducer<br />
focused near the billet back wall, following the style of Figure 1. Beam diameters (-6 dB) near the<br />
back wall are approximately 200 mils x 380 mils (axial x hoop).<br />
<strong>Evaluation</strong> of Transducers<br />
The two 7.5 MHzF/10 aperture elliptical transducers were evaluated in more detail than the<br />
preliminary evaluation reported in the previous quarterly. Frequency measurements were made<br />
using the echoes from #2FBH targets in 10” diameter calibration standards. Tables 1 and 2<br />
compares these frequency measurements with those supplied by the manufacturer, which had<br />
been measured on a flat brass target, located at the near focal point, in water.<br />
In order to assess the per<strong>for</strong>mance relative to the #1FBH sensitivity program goal, a number of<br />
scans were made using the 10 inch diameter Ti 64 ETC standards, which contain targets of various<br />
diameters down to 0.4 mm (1/64 inch). These scans were done as closely as possible to<br />
production inspection conditions, with the exceptions that the scan index was reduced to 0.01” in<br />
order to capture the peak signals, and the gate length was reduced where necessary to avoid back<br />
surface signals in the gate. For the zone 2 transducer, targets at 0.9”, 1.35” and 1.8” (start, center,<br />
Quarterly Report – January 1, 2002 –March 31, 2002<br />
print date/time: 6/6/2002 - 8:39 AM – Page 28