Presentation<br />

Machine safety<br />

Hoisting applications examples<br />

Example of Safety chain<br />

with Emergency stop to reach Performance level c<br />

1<br />

2<br />

3<br />

Examples of safety chain with<br />

emergency stop<br />

Safety chain to reach Performance level PLc / SIL1<br />

> > Safety module type XPS AXE + Emergency Stop with 1 NC contacts<br />

A typical example of hoisting for manually controlled machine - the operator has to<br />

monitor the load of the crane and check there are no people near to the load. The<br />

operator must be trained and informed how to drive the machine. The operator<br />

monitoring is the first safety barrier.<br />

In case of any trouble the operator must stop the machine by pushing at the<br />

emergency stop. The emergency stop is the second safety barrier. What is now the<br />

safety level required for the emergency stop?<br />

Because of the operator is monitoring the area, it can be considered that the<br />

frequency and the exposure times are short.<br />

Performance level required in this case is PLr = c<br />

To reach to required PL (PLc), the following architecture of Category 1 type<br />

(1-channel) is proposed:<br />

4<br />

Required<br />

performance<br />

level PLr<br />

3 x 400 VAC<br />

24 VDC<br />

5<br />

6<br />

7<br />

8<br />

9<br />

Starting point for the<br />

evaluation of the<br />

contribution to the<br />

risk reduction of a<br />

safety function<br />

S = Severity of injury<br />

S1 = Slight (normally reversible injury)<br />

S2 = Serious (normally irreversible) injury including death<br />

F = Frequency and/or exposure time to the hazard<br />

F1 = Seldom to less often and/or the exposure time is short<br />

F2 = Frequent to continuous and/or the exposure time is long<br />

P = Possibility of avoiding the hazard or limiting the<br />

harm<br />

P1 = Possible under specific conditions<br />

P2 = Scarcely possible<br />

(1) Fault relay contact<br />

Motor<br />

Brake<br />

control<br />

Brake<br />

R2C (1)<br />

R2A (1)<br />

Related products:<br />

> > Emergency stop - Harmony XB4, See chapter 8<br />

> > Limit switch OsiSense XF, See chapter 9<br />

> > Preventa Safety Module XPS AXE, See page 7/28<br />

> > TeSys contactor (nominal load), See chapter 5<br />

> > Variable Speed Drive Altivar 312, See chapter 6<br />

The performance level reached (reference SISTEMA and <strong>Schneider</strong> <strong>Electric</strong><br />

SISTEMA library) with this combination of products is<br />

> > PLc and<br />

> > PFH(1/h) of 2,31e -6 which corresponds to SIL1.<br />

10<br />

7/22