Presentation<br />

Machine safety<br />

Safety products level<br />

Functional safety and manufacturer<br />

reliability data of electromechanical<br />

components according to EN/ISO<br />

13849-1 and EN/IEC 62061<br />

Electromechanical components<br />

The following values apply to high or continuous demand mode of operations used<br />

in machinery applications.<br />

The B10 d<br />

value is given to a lifetime of 20 years, but is mainly limited by mechanical<br />

or contact wear.<br />

1<br />

Ranges<br />

B10 d<br />

Emergency stop push-buttons Ø 22 mm XB4 & XB5 1 500 000<br />

Pushbuttons Ø 22 mm XB4 & XB5 Spring return 10 000 000<br />

Pushbuttons Ø 22 mm XB4 & XB5 Double headed 2 000 000<br />

Pushbuttons Ø 22 mm XB4 & XB5 Push-push to release 1 000 000<br />

Selector switches Ø 22 mm XB4 & XB5 Non illuminated 2 000 000<br />

Selector switches Ø 22 mm XB4 & XB5 Illuminated 1 000 000<br />

Toggle switches Ø 22 mm XB4 & XB5 1 000 000<br />

Joystick controllers Ø 22 mm XB4 & XB5 2 000 000<br />

Emergency stop trip wire switches XY2 C 50 000<br />

Safety Limit switches with plunger or roller lever head XCS M/D/P 50 000 000<br />

Safety switches with key (guard switches) XCS 5 000 000<br />

Safety switches with key (electromagnet guard switches) XCS 5 000 000<br />

Safety switches with rotary opening head XCS 5 000 000<br />

Safety coded magnetic switches XCS DMC/DMP/DMR at 10mA 50 000 000<br />

contactors with nominal load 1 300 000<br />

contactors with mechanical load 20 000 000<br />

Cam switches K1/K2 2 000 000<br />

Motor control devices<br />

Contactors & Circuit breakers<br />

Please refer to Chapter 10 for catalogue information on contactors and circuit<br />

breakers.<br />

2<br />

3<br />

4<br />

5<br />

Variable Speed Drive Specific safety inputs<br />

Altivar 312, Altivar 32 and Altivar 71<br />

Please refer to Chapter 6 for catalogue information on the drives.<br />

The safety values of the<br />

presented variable speed<br />

drives are included in the<br />

<strong>Schneider</strong> <strong>Electric</strong><br />

SISTEMA library<br />

The analysis of the standard logic inputs show that there are conform<br />

according the following standards<br />

Standard<br />

LI (logic input)<br />

IEC 61508-5-2 / IEC 61508 SIL 1<br />

EN/IEC 62061<br />

SIL 1 CL<br />

EN 954-1 (1) Category 1<br />

EN ISO 13849-1 (2)<br />

Category 1 - PLc<br />

(1) According to table 6 of EN/IEC 62061 (2005) [DA6].<br />

(2) According to table 4 of EN ISO 13849-1 (2008) [DA2].<br />

Summary of safety-relevant data of the standard logical inputs of the range<br />

of variable speed drives: Altivar 312, Altivar 32 & Altivar 71<br />

> > “Sink” mode<br />

> > “Source” mode<br />

Altivar 32 Altivar 312 Altivar 71<br />

MTTF d<br />

(in year) 352 319 286<br />

DC<br />

46.7% 45.0% 42.1%<br />

None None None<br />

PL c c c<br />

Category 1 1 1<br />

SIL 1 1 1<br />

Altivar 32 Altivar 312 Altivar 71<br />

MTTF d<br />

(in year) 3854 1137 1115<br />

DC<br />

91.5% 73.75% 73.38%<br />

Medium Low Low<br />

PL d c c<br />

Category 2 2 2<br />

SIL 1 1 1<br />

6<br />

7<br />

8<br />

9<br />

10<br />