Architecture,<br />

Presentation<br />

Communication<br />

CANopen bus<br />

Integrated CANopen bus port on Modicon M238 logic<br />

controller, compact base for solutions with AFB<br />

1<br />

Tested Validated and Documented Architecture<br />

Modicon M238 logic controller, compact base for solutions with AFB<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

9<br />

10<br />

CANopen port<br />

The Modicon M238 logic controller bases TM238 LFDC24DTS0 and<br />

TM238 LFAC24DRS0 allow to act as CANopen master thanks to their integrated<br />

CANopen bus connector.<br />

The bus consists of a master station, the Modicon M238 controller type S and slave<br />

stations. The master is in charge of configuration, exchanges and diagnostics on the<br />

slaves.<br />

The CANopen bus is a communication type bus and allows management of various<br />

slaves such as:<br />

b Digital slaves,<br />

b Analogue slaves,<br />

b Variable speed controllers,<br />

b Motor starters,<br />

bbEtc.<br />

The Modicon M238 CANopen master type S controls up to 16 slaves, each with an<br />

input PDO (Process Data Object) and an output PDO.<br />

If a slave has more than one PDO, the maximum number of slaves is reduced by an<br />

equivalent number.<br />

CANopen conformity class<br />

<strong>Schneider</strong> <strong>Electric</strong> has defined the conformity classes for CANopen master and<br />

slave devices. Conformity classes are used to identify the services and levels of<br />

service supported by each CANopen device or product. These services are<br />

described in section 4 of our “Machines & Installations with industrial<br />

communications” catalogue.<br />

The table below shows product combination possibilities according to their conformity<br />

class.<br />

Conformity class<br />

Master<br />

product<br />

M10<br />

M20<br />

M30<br />

Slave device<br />

S10 S20 S30<br />

Combination possible: Modicon M238 controller master M10 classe with slave device<br />

S10 classe<br />

Use restriction: Modicon M238 controller type S master M10 class with slave device S20<br />

and S30 classes limits the level of service to that of the lower conformity class, either S20 or S30.<br />

CANopen architecture<br />

Wiring system, see page 4/6<br />

(1) 16 slaves max. with max. limit of: 32 RPDOs and 32 TPDOs<br />