10.07.2015 Views

ORiNOCO® Access Points Installation and Management Guide ...

ORiNOCO® Access Points Installation and Management Guide ...

ORiNOCO® Access Points Installation and Management Guide ...

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Managing the device using SNMP7.3 Viewing the MIB Objects1. After configuring the pre-requisite information, load the MIB file.2. Navigate to Proxim under the private node.• To view all the objects, right-click <strong>and</strong> select Walk. This will display all the default <strong>and</strong> configured objects.• To view a particular object, select a particular object, right-click <strong>and</strong> click Get. This will display the selected configuredobject.7.4 Configuring the MIB Objects7.4.1 To Configure the Scalar Objects1. Select the object, right-click <strong>and</strong> click Set. This will display the existing configured values.2. To make changes to the existing value, double-click the object. This displays the list of values for configuration. Select thedesired values <strong>and</strong> click Ok.3. Click Execute to store the changes in the temporary buffer <strong>and</strong> proceed to SysMgmtCfgCommit table to Commit thechanges.7.4.2 To Configure the Tabular Objects1. Select the object, right-click <strong>and</strong> click Get Table. This displays the Table List.2. From the menu, click Set <strong>and</strong> drag the table entry for which you want to make the changes to the Set window.: You can configure table by configuring each entry that is available for the table or update the entire table as asingle entry.3. Select the table, right-click, <strong>and</strong> click Set.4. In the Set window, to add a row for a table, enter “0” <strong>and</strong> this will automatically create a row for a particular table.5. Add the required parameters <strong>and</strong> configure those parameters.6. Click Execute <strong>and</strong> proceed to SysMgmtCfgCommit table to Commit the changes.7.4.3 To apply the changes to the flash memory1. Navigate to deviceMgmt > SysMgmtCfgCommit, right-click <strong>and</strong> click Set.2. Set the value as 1 <strong>and</strong> click OK.3. Click Execute, this would configure the new value to the flash memory.<strong>ORiNOCO®</strong> AP-800 <strong>and</strong> AP-8000 <strong>Installation</strong> <strong>and</strong> <strong>Management</strong> <strong>Guide</strong> 200

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!