Client: TNU-HANFORD <strong>RC</strong>-<strong>047</strong> W.O.#: 11343-606-001-9999-00<br />

LVL#: 0604L750 Date Received: 04-12-06<br />

SDG/<strong>SAF</strong>#: K1428/<strong>RC</strong>-<strong>047</strong><br />

METALS CASE NARRATIVE<br />

The following is a summary <strong>of</strong> <strong>the</strong> QC results accompanying <strong>the</strong> sample results. Lionville<br />

Laboratory (LvLI) certifies that all test results meet <strong>the</strong> requirements <strong>of</strong> NELAC except as noted<br />

below.<br />

All soil samples are reported on a dry weight basis unless requested by <strong>the</strong> client, required by <strong>the</strong><br />

method, or noted o<strong>the</strong>rwise.<br />

1. This narrative covers <strong>the</strong> analyses <strong>of</strong> 15 solid samples.<br />

2. The samples were prepared and analyzed in accordance with methods checked on <strong>the</strong> attached<br />

glossary. The samples are reported on a wet weight, ` as received' b asis.<br />

In file HG042701 for Mercury, sample J11KT6 read 2.07 µg2 in <strong>the</strong> digestate, followed by<br />

sample J11KT7, which read -0.728 µg/L in <strong>the</strong> digestate. These 2 samples were rerun in file<br />

HG050401 (3 days p ast hold) to confirm <strong>the</strong> results. Initially, J11KT6 read 4.48 µg/L, and<br />

J11KT7 read -2.73 µg/L. The CCB following <strong>the</strong>se samples dropped to -0.226 gg/L. The<br />

instrument was recalibrated, and <strong>the</strong>se 2 samples rerun once again, with 5-fold dilutions, and<br />

each followed by a blank. In this file, HG050402, both read between -0.1 and 0.1 µg/L.<br />

Results from HG042701 were reported, which were within <strong>the</strong> hold time for Mercu ry .<br />

3. All analyses were performed within <strong>the</strong> required holding times.<br />

4. All Initial and Continuing Calibration Verifications (ICV/CCVs) were within <strong>the</strong> 90-110%<br />

control limits (80-120% for Mercury).<br />

5. All Initial and Continuing Calibration Blanks (ICB/CCBs) were within control limits (less<br />

than <strong>the</strong> PQL).<br />

6. All preparation/method blanks (MB) were within method crite ria {less than <strong>the</strong> Practical<br />

Quantitation Limit (3X <strong>the</strong> IDL), or samples greater than 20X MB value). Refer to <strong>the</strong><br />

Inorganics Method Blank Data Summary .<br />

7. All ICP Interference Check Standards were within control limits.<br />

The re su lt<br />

s presented in this report relate only to <strong>the</strong> analy tical testing and conditions <strong>of</strong><strong>the</strong> samples at receipt and during storage. All pages <strong>of</strong>this report are<br />