Client: TNU-HANFORD <strong>RC</strong>-<strong>047</strong> WON: 11343-606-001-9999-00<br />

LVL#: 0604L904 Date Received: 04-28-06<br />

SDG/<strong>SAF</strong>4: K0303/<strong>RC</strong>-<strong>047</strong><br />

METALS CASE NARRATIVE<br />

The following is a summary <strong>of</strong> <strong>the</strong> QC results accomp anying <strong>the</strong> sample results. Lionville Laborato ry<br />

(LvLI) certi fi<br />

es that all test results meet <strong>the</strong> requirements <strong>of</strong> NELAC except as noted below.<br />

All soil samples are repo rted on a dry weight basis unless requested by <strong>the</strong> client, required by <strong>the</strong> method,<br />

or noted o<strong>the</strong>rwise.<br />

This narrative covers <strong>the</strong> analyses <strong>of</strong> 15 solid samples.<br />

2. The samples were prepared and analyzed in accordance with methods checked on <strong>the</strong> attached<br />

glossary. The samples are reported on a wet weight, `as received' basis.<br />

All samples were rerun for Aluminum, Be ryllium, and Copper, along with <strong>the</strong> Phosphorous<br />

analysis, due to sample matrix. The matrix spike <strong>of</strong> sample J11KK8, and samples J1 1L21 and<br />

J11L23 were rerun for Phosphorous due to high concen trations.<br />

3. All analyses were performed within <strong>the</strong> required holding ti mes.<br />

4. All Ini ti al and Con ti nuing Calibration Verifications (ICV/CCVs) were within <strong>the</strong> 90-110% con trol<br />

limits (80-120% for Mercury).<br />

5. All Ini tial and Continuing Calibration Blanks (ICB/CCBs) were within con trol limits (less than <strong>the</strong><br />

PQL).<br />

6. The preparation/method blanks for 2 analytes were outside method c riteria (less than <strong>the</strong> Prac ti cal<br />

Quantitation Limit (3X <strong>the</strong> IDL), or samples greater than 20X MB value). Refer to <strong>the</strong> Inorganics<br />

Method Blank Data Summary .<br />

a). The MB results for Aluminum and Uranium were greater than <strong>the</strong> Prac ti cal Quantitation Limit<br />

(PQL) (3 x <strong>the</strong> (IDL) Instrument Detection Level) and al l samples read less than 20 ti mes <strong>the</strong> MB<br />

concentration for Aluminum. However, no corrective ac ti on criteria for MBs were provided in<br />

SW846 method 6010B. The sample results were repo rted herein "uncorrected" for <strong>the</strong> levels<br />

found in <strong>the</strong> MB. All samples were below <strong>the</strong> IDL for Uranium.<br />

All ICP Interference Check Standards were within con trol limits.<br />

The re su lts presented in this re port relate only to <strong>the</strong> analytical testing and conditions <strong>of</strong><strong>the</strong> samples at receipt and during storage. All pages <strong>of</strong>this re po rt are<br />

integral pads <strong>of</strong><strong>the</strong> analy tical data The re fo re , this report should only be reproduced in its entirety <strong>of</strong> ^C pages.<br />

208 Welsh Pool Road • Exton, PA 19341- 1313 • (610) 280-<strong>300</strong>0 • Fax (610) 280-3<strong>047</strong>

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!