11.07.2015 Views

Galileo Sol.pdf

Galileo Sol.pdf

Galileo Sol.pdf

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

3. Diving with <strong>Galileo</strong>4-second intervals. In addition, the currentdepth is shown in inverted colors (white on ablack background) and in the lower left cornerMOD and the value of the MOD are displayed,also in inverted colors. Alternate information isaccessible as described in section 3.3.2, butafter 5 seconds the inverted MOD is againshown. This will not change until the diverascends 1m/3ft above the MOD. The audiblesignal persists until the diver ascends 1m/3ftabove the MOD.3.2.3 CNS O 2 = 100%EnglishIn LIGHT confi guration, the alarm messageMOD EXCEEDED is displayed in place ofthe no-stop information for 12 seconds,after which it is repeated in 4-secondintervals. In addition, the current depth isdisplayed in inverted colors (white on ablack background) and remains like thisuntil the diver ascends 1m/3ft above theMOD. The audible signal persists until thediver ascends 1m/3ft above the MOD. WARNINGWhen the CNS O 2 reaches 100% there isdanger of oxygen toxicity. Start procedure toterminate the dive.In CLASSIC confi guration, the alarm messageCNS O 2 = 100% is displayed in place of theno-stop or decompression information for 12seconds and during this time the audible signalgoes off. In addition, in the lower left corner, theCNS O 2 information is displayed in inverted colors(white on a black background) and remainsdisplayed until the CNS O 2 value drops under100%. Alternate information is accessible asdescribed in section 3.3.2, but after 5 secondsthe inverted CNS O 2 is again shown.In FULL confi guration, the alarm messageMOD EXCEEDED is displayed in place ofthe no-stop or decompression informationfor 12 seconds, after which it is repeated in4-second intervals. In addition, the currentdepth is shown in inverted colors (white on ablack background) and MOD and the valueof the MOD are displayed in place of the maxdepth, also in inverted colors. This will notchange until the diver ascends 1m/3ft abovethe MOD. The audible signal persists until thediver ascends 1m/3ft above the MOD.In LIGHT confi guration, the alarm messageCNS O 2 = 100% is displayed in place ofthe no-stop information for 12 secondsand during this time the audible signalgoes off. In addition, after the textmessage extinguishes, the CNS O 2 isdisplayed in inverted colors (white on ablack background) in the lower left corner,alternating every 4 seconds with the tankpressure information. This will remain so foras long as the CNS O 2 value is higher than100%. Alternate information is available asdescribed in section 3.3.3.45

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!