CITY 1.24 and 2.24 GN CITY 1.24 and 2.24 B/P
CITY 1.24 and 2.24 GN CITY 1.24 and 2.24 B/P
CITY 1.24 and 2.24 GN CITY 1.24 and 2.24 B/P
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
6.2 Connections<br />
Important notes:<br />
• Before connecting the boiler to an existing installation,<br />
the installation must be thoroughly rinsed out<br />
using an appropriate product to prevent sludge reaching<br />
the heater body of the new boiler.<br />
6.2.1 Installing the backplate<br />
See the installation instruction sheet supplied in the<br />
backplate pack.<br />
6.2.2 Water <strong>and</strong> gas connections<br />
With 8 or 12 litre expansion tanks, the connections<br />
can be made from below, from above or from the rear.<br />
• Central heating connection<br />
Copper bush for connection to 16/18 mm dia. indoor<br />
tube or 20/22 mm dia. outdoor tube.<br />
• Domestic hot water connection<br />
Copper bush for connection to 14/16 mm dia. indoor<br />
tube or 18/20 mm dia. outdoor tube.<br />
In hard water areas (hardness >25) we recommend a<br />
water softener upstream of the boiler.<br />
• Gas connection<br />
Conform to the applicable provisions <strong>and</strong> in particular<br />
gas installation specification. A shut-off valve must<br />
always be installed as close as possible to the boiler.<br />
The copper bush is for 16/18 mm dia. indoor copper<br />
tube.<br />
Operating pressure<br />
20 mbar for H natural gas H (G20)<br />
25 mbar for H natural gas L (G25)<br />
29 mbar for butane (G30)<br />
37 mbar for propane (G31)<br />
11<br />
• If different metals are used, such as copper <strong>and</strong> aluminium,<br />
a corrosion inhibitor must be used.<br />
Central<br />
heating outlet<br />
ø18<br />
Tube-cutter<br />
D.H.W<br />
ø16<br />
Gas<br />
inlet<br />
ø18<br />
Connections<br />
D.C.W<br />
ø16<br />
From the rear<br />
From above<br />
From below<br />
Central<br />
heating return<br />
ø18<br />
ø18 od ø16 od ø18 od ø16 od ø18 od<br />
ø20 id ø18 id ø18 id ø20 id<br />
8666N130<br />
All nested connections to the gas tube must be<br />
made using sleeves purchased off the shelf.<br />
8666N081