8.5 Air bleed<br />
1<br />
2<br />
Open the stopper of the automatic bleeder in<br />
the top rear corner of the boiler.<br />
Domestic hot water heat exchanger<br />
(<strong>CITY</strong> <strong>2.24</strong> only)<br />
- Bleed the domestic hot water heat exchanger<br />
by unscrewing the bleeder slightly.<br />
- To accelerate bleeding, alternate between<br />
calling for heat <strong>and</strong> hot water.<br />
- Tighten the bleeder after bleeding the air.<br />
Central heating installation<br />
- Check that all of the installation has been bled<br />
correctly.<br />
8.6 Adjusting the domestic hot water flow rate<br />
(<strong>CITY</strong> <strong>2.24</strong> only)<br />
The maximum domestic hot water flow rate is limited<br />
to 10 l/min by the flow rate controller which is mounted<br />
on the flow rate detector (item 43 § 3).<br />
This maximum flow rate can be reduced in 2 ways:<br />
- 1. by adjusting the screw 4.1 (8 mm Allen key),<br />
- 2. by replacing the 10 l/min controller with an<br />
8 l/min controller.<br />
The 8 l/min controller (package HA 218) is supplied<br />
with fitting instructions.<br />
17<br />
8666N105 A<br />
8.7 Adjustment of the maximum temperature position of the DHW exchanger : T MM<br />
(<strong>CITY</strong> <strong>2.24</strong> only)<br />
The DHW exchanger, when activated, is maintained<br />
at the projected holding temperature DHW - 5° C or<br />
at the maximum T MM.<br />
Adjustment Display<br />
- Press the button for 5 seconds (55°C)<br />
- Press repeatedly to select the desired<br />
maximum temperature position TMM<br />
To exit the display, wait 5 minutes without<br />
pressing anything<br />
1<br />
2<br />
4.1<br />
8666N106 B