CITY 1.24 and 2.24 GN CITY 1.24 and 2.24 B/P
CITY 1.24 and 2.24 GN CITY 1.24 and 2.24 B/P
CITY 1.24 and 2.24 GN CITY 1.24 and 2.24 B/P
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
1. GENERAL<br />
1.1 Description<br />
<strong>CITY</strong> <strong>1.24</strong> wall hung gas boilers are for central heating<br />
only. They can be associated with 50, 80 or 150<br />
litre storage tanks to produce domestic hot water.<br />
<strong>CITY</strong> <strong>2.24</strong> boilers provide central heating <strong>and</strong> instantaneous<br />
domestic hot water.<br />
They use natural gas or butane/propane.<br />
<strong>CITY</strong> <strong>1.24</strong> <strong>GN</strong> <strong>and</strong> <strong>CITY</strong> <strong>2.24</strong> <strong>GN</strong> boilers are factory<br />
set for use with natural gas.<br />
<strong>CITY</strong> <strong>1.24</strong> B/P <strong>and</strong> <strong>CITY</strong> <strong>2.24</strong> B/P boilers are factory<br />
set for use with butane/propane.<br />
The boiler output can be varied between 10 <strong>and</strong> 24<br />
kW for central heating <strong>and</strong> 8 <strong>and</strong> 24 kW for domestic<br />
hot water.<br />
1.2 Approvals<br />
3<br />
These boilers are supplied in 2 packs:<br />
- backplate pack: water, gas <strong>and</strong> drain connections<br />
(safety valve, disconnector <strong>and</strong> domestic hot water<br />
pot bleeder on the <strong>2.24</strong> model).<br />
- boiler pack.<br />
Note:<br />
An extended height backplate must be used for boilers<br />
associated with an 80 litre tank.<br />
Boiler <strong>2.24</strong> <strong>GN</strong> <strong>2.24</strong> B/P <strong>1.24</strong> <strong>GN</strong> <strong>1.24</strong> B/P<br />
CE No. CE-0085 AT 0282<br />
Category II 2E+ 3+<br />
Type B11 BS<br />
Combustion product removal Flue liner<br />
Ignition Automatic<br />
Gas Natural gas Butane/Propane Natural gas Butane/Propane<br />
<strong>CITY</strong> boilers conform to the following European directives<br />
<strong>and</strong> st<strong>and</strong>ards:<br />
90/396 EEC Gas appliance directives<br />
Applicable st<strong>and</strong>ards: EN 297 <strong>and</strong> EN 625.<br />
73/23 EEC Low voltage directives<br />
Applicable st<strong>and</strong>ards: EN 60.335.1<br />
89/336 EEC EMC directives<br />
Applicable st<strong>and</strong>ards: EN 50.081.1/<br />
EN 50.082.1./EN 55.014<br />
92/42 EEC Efficiency directives<br />
★★ CE