27.11.2012 Views

CITY 1.24 and 2.24 GN CITY 1.24 and 2.24 B/P

CITY 1.24 and 2.24 GN CITY 1.24 and 2.24 B/P

CITY 1.24 and 2.24 GN CITY 1.24 and 2.24 B/P

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

1. GENERAL<br />

1.1 Description<br />

<strong>CITY</strong> <strong>1.24</strong> wall hung gas boilers are for central heating<br />

only. They can be associated with 50, 80 or 150<br />

litre storage tanks to produce domestic hot water.<br />

<strong>CITY</strong> <strong>2.24</strong> boilers provide central heating <strong>and</strong> instantaneous<br />

domestic hot water.<br />

They use natural gas or butane/propane.<br />

<strong>CITY</strong> <strong>1.24</strong> <strong>GN</strong> <strong>and</strong> <strong>CITY</strong> <strong>2.24</strong> <strong>GN</strong> boilers are factory<br />

set for use with natural gas.<br />

<strong>CITY</strong> <strong>1.24</strong> B/P <strong>and</strong> <strong>CITY</strong> <strong>2.24</strong> B/P boilers are factory<br />

set for use with butane/propane.<br />

The boiler output can be varied between 10 <strong>and</strong> 24<br />

kW for central heating <strong>and</strong> 8 <strong>and</strong> 24 kW for domestic<br />

hot water.<br />

1.2 Approvals<br />

3<br />

These boilers are supplied in 2 packs:<br />

- backplate pack: water, gas <strong>and</strong> drain connections<br />

(safety valve, disconnector <strong>and</strong> domestic hot water<br />

pot bleeder on the <strong>2.24</strong> model).<br />

- boiler pack.<br />

Note:<br />

An extended height backplate must be used for boilers<br />

associated with an 80 litre tank.<br />

Boiler <strong>2.24</strong> <strong>GN</strong> <strong>2.24</strong> B/P <strong>1.24</strong> <strong>GN</strong> <strong>1.24</strong> B/P<br />

CE No. CE-0085 AT 0282<br />

Category II 2E+ 3+<br />

Type B11 BS<br />

Combustion product removal Flue liner<br />

Ignition Automatic<br />

Gas Natural gas Butane/Propane Natural gas Butane/Propane<br />

<strong>CITY</strong> boilers conform to the following European directives<br />

<strong>and</strong> st<strong>and</strong>ards:<br />

90/396 EEC Gas appliance directives<br />

Applicable st<strong>and</strong>ards: EN 297 <strong>and</strong> EN 625.<br />

73/23 EEC Low voltage directives<br />

Applicable st<strong>and</strong>ards: EN 60.335.1<br />

89/336 EEC EMC directives<br />

Applicable st<strong>and</strong>ards: EN 50.081.1/<br />

EN 50.082.1./EN 55.014<br />

92/42 EEC Efficiency directives<br />

★★ CE