4. CONTROL PANEL<br />

A B B1 B2 C D E F<br />

G H I J K L<br />

M<br />

A. Temperature display<br />

- displays the temperature at the central heating<br />

outlet or the domestic hot water outlet when water<br />

is drawn off.<br />

B. Domestic hot water heat exchanger temperature<br />

button (<strong>CITY</strong> <strong>2.24</strong> only).<br />

This function is factory set to the activated<br />

position.<br />

This provides maximum user comfort.<br />

When the boiler is switched on, indicator B2 is on<br />

to show that this function is activated.<br />

The function can be deactivated, for example in<br />

the event of prolonged absence, by pressing button<br />

B (indicator B2 turns off).<br />

Disconnection of the output supply does not modify<br />

the selected operating mode.<br />

Note:<br />

- if indicators B1 <strong>and</strong> B2 are both turned on, the<br />

burner has been ignited to heat the domestic hot<br />

water supply.<br />

- B2 flashes when the holding position is activated<br />

by bypassing the Easymatic control.<br />

C. Safety indicator<br />

D. Unlocking button<br />

- used to reset the boiler from failsafe mode<br />

E. “clean” button<br />

- forces operation of the boiler<br />

• press <strong>and</strong> hold for 5 seconds (display shows )<br />

to force the burner to the P min position<br />

• press again (display shows ) to force<br />

the burner to the P max (24 kW) position<br />

8<br />

F. “Installer” button<br />

8666N020<br />

G. 3-position switch<br />

- off/anti-freeze<br />

- central heating <strong>and</strong> domestic hot water (winter)<br />

- domestic hot water (summer)<br />

H. “Central heating” on indicator<br />

- on when the boiler is ignited to heat the water in<br />

the central heating circuit<br />

I. Central heating temperature control<br />

- range from 40 to 90°C (click stop at 75°C)<br />

J. Flame present indicator<br />

- on when the burner is ignited<br />

K. Domestic hot water temperature control<br />

- range from 40 to 60°C (click stop at 55°C)<br />

L. “Domestic hot water” on indicator<br />

- on when the burner is ignited to heat the domestic<br />

hot water supply<br />

M. Pressure indicator<br />

- indicates the pressure in the central heating<br />

circuit (0.5 to 2.5 bars)