10.3 Domestic hot water<br />

If the domestic hot water heat exchanger is affected<br />

by limescale, clean it by connecting a descaling<br />

pump to the two domestic water connectors ➂.<br />

Use only products suitable for this purpose.<br />

To obtain access to the domestic water connectors:<br />

1 Tilt the control panel forward after removing the<br />

2 fixing screws at the sides.<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

Disconnect the electrical output supply<br />

<strong>and</strong> the gas supply from the boiler.<br />

Close the domestic water inlet <strong>and</strong> outlet<br />

valves <strong>and</strong> open the drain screws.<br />

Protect the control panel from being<br />

splashed with descaling product.<br />

Unscrew the two 1/2”nuts on the domestic water<br />

heat exchanger (24 mm wrench).<br />

Unscrew slightly the 3/4” nut on the domestic<br />

hot water outlet (30 mm wrench).<br />

Pivot the domestic hot water outlet tube towards<br />

the front.<br />

Unscrew the 3/4" nut on the domestic cold water<br />

inlet pipe (30 mm wrench).<br />

Remove the domestic cold water inlet pipe.<br />

Connect the descaling device to the two 1/2"<br />

exchanger connectors.<br />

After descaling, reassembly is the reverse of the<br />

above procedure.<br />

Replace the seals with new seals.<br />

10.4 Cleaning the ”cold water” filter<br />

(<strong>CITY</strong> <strong>2.24</strong> only)<br />

1<br />

2<br />

3<br />

4<br />

Turn the tap off (6mm spanner) to avoid any drawing<br />

off from the domestic circuit (kitchen,<br />

bathroom, etc.) <strong>and</strong> major discharge when the<br />

filter is dismantled.<br />

Unscrew the drain cock after connecting a hose<br />

(dimension: 8 mm).<br />

Unscrew the adjustment door-filter-tap with a<br />

17mm spanner.<br />

If required, remove the filter <strong>and</strong> clean it with a<br />

soft brush<br />

- replace the filter on the filter-door <strong>and</strong> screw it<br />

into the tap (17mm spanner)<br />

- turn off the drain cock<br />

- turn on the tap (6mm spanner).<br />

25<br />

1<br />

�<br />

5<br />

3<br />

7<br />

4 6<br />

�<br />

�<br />

8666N182<br />

�<br />

8666N293