6.4 Fitting the boiler casing<br />

8666N092<br />

7. PRESSURE SETTING AND CALIBRATED INJECTOR AND DIAPHRAGM<br />

MARKINGS<br />

Equipment<br />

<strong>CITY</strong> <strong>1.24</strong> <strong>and</strong> <strong>2.24</strong><br />

Burner pressure <strong>and</strong> gas flow rate<br />

<strong>CITY</strong> <strong>1.24</strong> <strong>and</strong> <strong>2.24</strong><br />

ø<br />

mm<br />

Burner Natural gas H <strong>and</strong> L 1.35<br />

injectors Butane / Propane 0.8<br />

Diaphragm Natural gas H <strong>and</strong> L 5.2<br />

Butane / Propane 4.2<br />

Output nominal minimum<br />

Burner Nat. gas H mbar 6.5 1.0<br />

pressure Nat. gas L mbar 7.9 1.4<br />

Butane mbar 19.1 2.5<br />

Propane mbar 24.1 3.4<br />

Flow Nat. gas H m 3 /h 2.79 1.01<br />

rate * Nat. gas L m 3 /h 2.97 1.07<br />

Butane kg/h 2.08 0.75<br />

Propane kg/h 2.05 0.74<br />

15<br />

Note : fit the front panel after commissioning<br />

the boiler.<br />

* 1013 mbar at 15°C<br />

8666N093