8.8.2 Burner safety check<br />
- With the burner lit, cut off the gas supply by closing<br />
the shut-off valve.<br />
- Check the reaction of the safety system:<br />
the alarm indicator C should turn on <strong>and</strong> the display<br />
A should alternately indicate <strong>and</strong> .<br />
- Open the gas valve <strong>and</strong> press the reset button D.<br />
8.8.3 Safety thermostat check<br />
The safety thermostat should shut down the boiler if<br />
the temperature at the central heating outlet exceeds<br />
105°C.<br />
- Press the “clean” button E for 5 seconds. The dis-<br />
play A shows .<br />
- Press button E briefly. The display A shows .<br />
- Press button E a third time for 5 seconds. This<br />
forces the burner to minimum output <strong>and</strong> the display<br />
A indicates alternately <strong>and</strong> the original temperature.<br />
- Close the central heating flow <strong>and</strong> return valves 1 <strong>and</strong><br />
5 using an 8 mm wrench.<br />
The outlet temperature is no longer limited by the<br />
control system <strong>and</strong> the safety thermostat should shut<br />
down the burner.<br />
When the temperature exceeds 100°C <strong>and</strong> the safety<br />
thermostat has not yet tripped, the display indicates<br />
alternately <strong>and</strong> .<br />
If the burner is turned off, the boiler cools <strong>and</strong> shortly<br />
afterwards the burner is ignited again <strong>and</strong> the rise<br />
in temperature continues:<br />
- when the burner is shut off by the safety thermostat:<br />
• indicator C turns on<br />
• the display alternately indicates <strong>and</strong> .<br />
- To restart the burner:<br />
• open central heating flow <strong>and</strong> return valves 1<br />
<strong>and</strong> 5<br />
• press button D.<br />
19<br />
8666N111 A<br />
8666N218<br />
8666N219<br />
A C D<br />
A<br />
1 5<br />
A<br />
8666N108 B<br />
If the boiler has not shut down 2 minutes<br />
after shutting the valves, disconnect the boiler<br />
from the mains electrical output supply.<br />