8.8.2 Burner safety check<br />

- With the burner lit, cut off the gas supply by closing<br />

the shut-off valve.<br />

- Check the reaction of the safety system:<br />

the alarm indicator C should turn on <strong>and</strong> the display<br />

A should alternately indicate <strong>and</strong> .<br />

- Open the gas valve <strong>and</strong> press the reset button D.<br />

8.8.3 Safety thermostat check<br />

The safety thermostat should shut down the boiler if<br />

the temperature at the central heating outlet exceeds<br />

105°C.<br />

- Press the “clean” button E for 5 seconds. The dis-<br />

play A shows .<br />

- Press button E briefly. The display A shows .<br />

- Press button E a third time for 5 seconds. This<br />

forces the burner to minimum output <strong>and</strong> the display<br />

A indicates alternately <strong>and</strong> the original temperature.<br />

- Close the central heating flow <strong>and</strong> return valves 1 <strong>and</strong><br />

5 using an 8 mm wrench.<br />

The outlet temperature is no longer limited by the<br />

control system <strong>and</strong> the safety thermostat should shut<br />

down the burner.<br />

When the temperature exceeds 100°C <strong>and</strong> the safety<br />

thermostat has not yet tripped, the display indicates<br />

alternately <strong>and</strong> .<br />

If the burner is turned off, the boiler cools <strong>and</strong> shortly<br />

afterwards the burner is ignited again <strong>and</strong> the rise<br />

in temperature continues:<br />

- when the burner is shut off by the safety thermostat:<br />

• indicator C turns on<br />

• the display alternately indicates <strong>and</strong> .<br />

- To restart the burner:<br />

• open central heating flow <strong>and</strong> return valves 1<br />

<strong>and</strong> 5<br />

• press button D.<br />

19<br />

8666N111 A<br />

8666N218<br />

8666N219<br />

A C D<br />

A<br />

1 5<br />

A<br />

8666N108 B<br />

If the boiler has not shut down 2 minutes<br />

after shutting the valves, disconnect the boiler<br />

from the mains electrical output supply.<br />