5. HYDRAULIC SPECIFICATIONS<br />

5.1 Circulator<br />

The circulator incorporated in the boiler is equipped<br />

with a 3-speed motor with a output consumption of<br />

80 W supply. It is factory-set on high.<br />

Remark<br />

For boilers also producing domestic hot water (City<br />

<strong>2.24</strong> or <strong>1.24</strong> plus storage cylinder), the circulator can<br />

if required be set on intermediate. It is nevertheless<br />

recommended, for reasons of comfort, to leave it on<br />

high.<br />

For installations requiring greater hydraulic performance<br />

it is possible to replace the motor with a more<br />

outputful one (pack HA 209) with a output consumption<br />

of 93 W.<br />

5.2 8 litre expansion tank<br />

<strong>CITY</strong> boilers are equipped as st<strong>and</strong>ard with an 8 litre<br />

tank (initial pressure 0.75 bar). The total water volume<br />

is determined in accordance with the static head<br />

of the installation <strong>and</strong> for an average water temperature<br />

of 80°C (flow: 90/return:70).<br />

5.3 12 litre expansion tank<br />

<strong>CITY</strong> boilers can optionally be fitted with a 12 litre<br />

expansion tank (initial pressure 0.75 bar) (pack HA<br />

208).<br />

6. INSTALLATION<br />

6.1 Regulations<br />

Installation <strong>and</strong> maintenance regulations<br />

The appliance must be installed <strong>and</strong> maintained by a<br />

qualified professional in accordance with statutory<br />

requirements.<br />

9<br />

Head (mcE)<br />

6<br />

5<br />

4<br />

3<br />

2<br />

1<br />

GV<br />

MV<br />

PV<br />

GV<br />

MV<br />

PV<br />

0<br />

0 200 400 600 800 1000 1200<br />

Flowrate (l/h)<br />

8666N079<br />

1. PV : low speed<br />

2. MV : medium speed<br />

3. GV : high speed<br />

Static head 5 6 7 8 9 10<br />

in metres up to<br />

Total water<br />

volume<br />

Establishments receiving the public<br />

Installation regulations:<br />

80 W motor<br />

93 W motor (option)<br />

138 129 120 111 102 92<br />

Static head 5 6 7 8 9 10<br />

in metres up to<br />

Total water<br />

volume<br />

213 204 195 186 177 167<br />

The appliance must be installed <strong>and</strong> maintained in<br />

accordance with statutory requirements.