3. SCHEMATICS<br />

<strong>2.24</strong> <strong>and</strong> <strong>1.24</strong> boilers<br />

1. Central heating outlet valve<br />

2. Domestic hot water outlet valve<br />

3. Gas inlet valve<br />

4. Cold water inlet valve:<br />

- water flow open / close<br />

- flowrate adjustment<br />

- filter (removable from below)<br />

5. Central heating return valve<br />

6. Drain screw<br />

7. Water flowrate sensor<br />

8. Domestic hot water outlet sensor<br />

9. Domestic hot water heat<br />

exchanger drain screw<br />

10. Domestic hot water heat exchanger<br />

maintain temperature sensor<br />

11. Domestic hot water heat<br />

exchanger air bleed screw<br />

12. Central heating / domestic hot<br />

water changeover valve drive motor<br />

13. Central heating / domestic hot<br />

water changeover valve<br />

14. Electronic pressure gauge<br />

15. Degassing chamber<br />

16. Circulator motor<br />

17. Burner pressure offtake<br />

18. Ionisation sensor<br />

19. Expansion tank<br />

20. Expansion tank inflation valve<br />

21. Automatic bleeder<br />

22. Anti-backflow draw cup-out<br />

23. Combustion product connector<br />

24. Combustion product anti-overflow<br />

sensor<br />

25. Main heat exchanger<br />

26. Central heating outlet temperature<br />

sensor<br />

27. Safety thermostat<br />

28. Combustion chamber<br />

29. Burner<br />

30. Igniter electrodes<br />

31. Gas valve modulator<br />

32. Gas valve safety valves<br />

33. Gas supply pressure offtake<br />

34. Modulator gas valve<br />

35. Domestic hot water heat<br />

exchanger (<strong>2.24</strong> only)<br />

36. Central heating circuit safety valve<br />

37. Central heating circuit by-pass pipe<br />

38. Disconnector<br />

42. Igniter<br />

43. Domestic hot water flow rate<br />

controller (10 l/min)<br />

44. Non return valve<br />

* If boiler is connected to domestic hot<br />

water storage tank<br />

24<br />

25<br />

26<br />

27<br />

28<br />

29<br />

30<br />

31<br />

32<br />

42<br />

33<br />

34<br />

35<br />

44<br />

36<br />

37<br />

38<br />

7<br />

TS<br />

TAF<br />

S1<br />

Central<br />

heating<br />

6<br />

M<br />

2<br />

1<br />

M<br />

2<br />

1<br />

S2<br />

S3<br />

6 6 6<br />

outlet<br />

1 2 3 4 5<br />

Central<br />

heating<br />

outlet<br />

D.H.W.<br />

Domestic*<br />

hot water<br />

storage tank<br />

primary outlet<br />

Gas<br />

inlet<br />

D.C.W. Central<br />

heating<br />

return<br />

gas Domestic*<br />

inlet hot water<br />

storage tank<br />

primary return<br />

Central<br />

heating<br />

return<br />

<strong>CITY</strong> <strong>2.24</strong><br />

23<br />

22<br />

21<br />

20<br />

19<br />

18<br />

17<br />

16<br />

15<br />

14<br />

13<br />

12<br />

11<br />

10<br />

43 9<br />

8<br />

7<br />

<strong>CITY</strong> <strong>1.24</strong><br />

8666N016F