Functions of the accessoriesThe table below lists a few functions that can be obtained byselecting the appropriate accessories from among those provided.Several of the functions listed may be needed at the sametime, depending on how the <strong>circuit</strong>-breaker is used. See therelative section for a detailed description of the individual accessories.FunctionComponentsRemote control• Opening release• Closing release• Geared motor for automatic charging of the closing springsRemote signalling or actuation of automatic functionsdepending on the state (open-closed-tripped) or position(racked-in, test isolated, racked-out) of the <strong>circuit</strong>-breaker.• Circuit-breaker open-closed auxiliary contacts• Circuit-breaker racked-in, test isolated, racked-out auxiliarycontacts (withdrawable <strong>circuit</strong>-breaker only)• Contact for electrical signalling of overcurrent release tripped• Contact for signalling under<strong>voltage</strong> release de-energized• Contact for signalling springs chargedRemote opening for various needs, including:– manual emergency control– opening dependent on tripping of other interruptiondevices or system automation needs (1) .• Opening or under<strong>voltage</strong> release5Automatic opening of the <strong>circuit</strong>-breaker for under<strong>voltage</strong>(for example, when operating asynchronous motors)• Instantaneous or time delay under<strong>voltage</strong> release (2)• Contact for signalling under<strong>voltage</strong> release energizedIncreased degree of protection• IP54 door protectionMechanical safety locks for maintenance or functionalrequirements for interlocking two or more <strong>circuit</strong>-<strong>breakers</strong>• Key lock in open position• Padlock device in open position• Key lock and padlocks in racked-in, test isolated, racked-outpositionAutomatic switching of power supplies• Mechanical interlock between two or three <strong>circuit</strong>-<strong>breakers</strong>• Automatic transfer switches - ATS021-ATS022(1) Examples:– <strong>circuit</strong>-<strong>breakers</strong> on <strong>Low</strong> Voltage side of parallel transformers that must openautomatically when the Medium Voltage side device opens.– automatic opening for control by external relay (under<strong>voltage</strong>, residual current, etc.).(2) The time-delay device is recommended when unwanted operation due to temporary<strong>voltage</strong> drops, is to be avoided (for functional or safety reasons).5/2<strong>ABB</strong> SACE

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!