12.07.2015 Views

Emax Low voltage air circuit-breakers - ABB Download Center

Emax Low voltage air circuit-breakers - ABB Download Center

Emax Low voltage air circuit-breakers - ABB Download Center

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Ordering codesOrder examples1) Extra codesInstructions for orderingStandard version <strong>Emax</strong> series <strong>circuit</strong>-<strong>breakers</strong> are identified by means of commercial codesthat can be altered by adding the following variables:• Codes for Terminal Kits for fixed <strong>circuit</strong>-<strong>breakers</strong> (other than horizontal rear)• Extra codes for Current Transformer Settings (for current values below rated)• Extra codes for special Version for rated service <strong>voltage</strong>s up to 1150V ACThe above types of variables can also be requested simultaneously on the same <strong>circuit</strong>-breaker.The “Extra codes” indicate variables that are not in addition to, but in replacement of the thosefound in the basic <strong>circuit</strong>-breaker.For this reason, these commercial codes can only be ordered installed on the <strong>circuit</strong>-breakerand not as loose parts.For releases (which already include the Dialogue Unit) and Current Transformers for suppliesas spare parts for replacement by the customer, please see the coding section “ProtectionReleases and Current Transformers which can be supplied separately”.Numerical examples• Terminal Kit Codes for fixed <strong>circuit</strong>-breaker (other than horizontal rear)The codes indicate 3 or 4 pieces (for mounting on top or bottom terminals).To convert a complete <strong>circuit</strong>-breaker, in the order specify 2 identical kits or 2 different kits formixed terminals.For mixed solutions, the first code indicates the 3 or 4 terminals to be mounted above, while thesecond indicates the 3 or 4 terminals to be mounted below.Example no. 1<strong>Emax</strong> E3N 3 poles fixed with Vertical Rear terminals (VR)1SDA056148R1 E3N 32 PR122/P-LSI-In=3200A 3p F HR1SDA038054R1 KIT 1/2 3p F HR>F VR E31SDA038054R1 KIT 1/2 3p F HR>F VR E3Example no. 2<strong>Emax</strong> E3N 3 poles fixed with top Vertical Rear (VR) and bottom Front (F) terminals1SDA056148R1 E3N 32 PR122/P-LSI-In=3200A 3p F HR1SDA038054R1 KIT 1/2 3p F HR>F VR E31SDA038064R1 KIT 1/2 3p F HR>F F E3Example no. 3<strong>Emax</strong> E3N 3 poles fixed with top Horizontal Rear terminals (HR) standard and bottom Vertical Rear terminals (VR)1SDA056148R1 E3N 32 PR122/P-LSI IN=3200A 3p F HR1SDA050230R1 Kit 1/2 3p F HR1SDA038054R1 Kit 1/2 3p F HR > F VR E3• Extra codes for Current Transformer Settings (for current values below rated)Example no. 4<strong>Emax</strong> E3N 3200 3 poles fixed In=2000A1SDA056148R1 E3N 32 PR122/P-LSI-In=3200A 3p F HR1SDA058242R1 rating plug In=2000A E2-4IEC E3-4UL EX.C• Extra codes for Special Version for rated service <strong>voltage</strong>s up to 1150V AC9Example no. 5<strong>Emax</strong> E3H/E 2000 3 poles fixed (version up to 1150V AC)1SDA056432R1 E3H 20 PR121/P-LI-In=2000A 3p F HR1SDA048534R1 Special 1150V AC version <strong>Emax</strong> E3H/E20 <strong>circuit</strong>-breaker9/64<strong>ABB</strong> SACE

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!