12.07.2015 Views

Emax Low voltage air circuit-breakers - ABB Download Center

Emax Low voltage air circuit-breakers - ABB Download Center

Emax Low voltage air circuit-breakers - ABB Download Center

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Installation in switchgearChoosing the type of <strong>circuit</strong>-breakerConnecting the main <strong>circuit</strong>-breaker<strong>circuit</strong>sWhen designing switchgear, one must always bear in mind theproblem of making the most rational connections between the<strong>circuit</strong>-breaker and main busbar system and from the busbarsto the users. The SACE <strong>Emax</strong> series offers switchgear manufacturersa range of options to satisfy different <strong>circuit</strong>-breakerconnection requirements.The figures below give some indications for terminal selection.Horizontal rear terminalsVertical rear terminalsFront terminalsFlat rear terminals3For switchgear with access fromthe rearFor switchgear with access fromthe rearFor wall-mounted switchgear,with access from the front only(withdrawable version only) Forswitchgear with access from therearDegrees of protectionA number of solutions have been adopted on SACE <strong>Emax</strong> <strong>circuit</strong>-<strong>breakers</strong>to achieve IP20 degree of protection for fixed orwithdrawable <strong>circuit</strong>-<strong>breakers</strong>, excluding the terminals, and IP30for their front parts using a flange. Automatic shutters have beendesigned for the fixed parts of withdrawable <strong>circuit</strong>-<strong>breakers</strong>which can be locked using padlock devices to allow maintenanceon the load side or on the power-supply side of the fixedpart.A transparent protective cover is also available on request, tocompletely segregate the front of the <strong>circuit</strong>-breaker, reachingIP54 degree of protection. In any case, the front panel and protectiontrip unit with the relative indications remain completelyvisible.IP20 Fixed or withdrawable version <strong>circuit</strong>-breaker, excludingthe terminals.IP30 Front parts of the <strong>circuit</strong>-<strong>breakers</strong> (using a flange).IP54 Fixed or withdrawable version <strong>circuit</strong>-breaker, fitted withtransparent protective cover to be fixed onto the frontof the switchgear (on request).1SDC200089F00013/4<strong>ABB</strong> SACE

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!