12.07.2015 Views

Emax Low voltage air circuit-breakers - ABB Download Center

Emax Low voltage air circuit-breakers - ABB Download Center

Emax Low voltage air circuit-breakers - ABB Download Center

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Automatic <strong>circuit</strong>-<strong>breakers</strong> for applicationsup to 1150V AC1SDC200061F0001SACE <strong>Emax</strong> <strong>circuit</strong>-<strong>breakers</strong> can be supplied in a special version for rated service <strong>voltage</strong>s upto 1150 V in AC.Circuit-<strong>breakers</strong> in this version are identified by the letters of the standard range (rated service<strong>voltage</strong> up to 690 V AC) plus “/E”, and are derived from the corresponding standard SACE <strong>Emax</strong><strong>circuit</strong>-<strong>breakers</strong>. They offer the same versions and accessories as the latter. The SACE <strong>Emax</strong>range of <strong>circuit</strong>-<strong>breakers</strong> for applications up to 1150V in AC can be either fixed and withdrawable,in both three-pole and four-pole versions. SACE <strong>Emax</strong>/E <strong>circuit</strong>-<strong>breakers</strong> are especiallysuitable for installation in mines, oil and chemical plants, and for traction. This range of <strong>Emax</strong>was tested at a <strong>voltage</strong> of 1250VAC.The table below shows the electrical specifications of the range.2E2B/E E2N/E E3H/E E4H/E** E6H/E**Max rated uninterruptedcurrent (at 40 °C) [A] 1600 2000 1250 1600 2000 1250 1600 2000 2500 3200 3200 4000 4000 5000 6300Rated service <strong>voltage</strong> Ue [V~] 1150 1150 1150 1150 1150 1150 1150 1150 1150 1150 1150 1150 1150 1150 1150Rated insulation <strong>voltage</strong> Ui [V~] 1250 1250 1250 1250 1250 1250 1250 1250 1250 1250 1250 1250 1250 1250 1250Rated ultimate breaking capacityunder short-<strong>circuit</strong> Icu1000 V [kA] 20 20 30 30 30 50 50 50 50 50 65 65 65 65 651150 V [kA] 20 20 30 30 30 30 30 30 30 30 65 65 65 65 65Rated service breaking capacityunder short-<strong>circuit</strong> Ics1000 V [kA] 20 20 30 30 30 50 50 50 50 50 65 65 65 65 651150 V [kA] 20 20 30 30 30 30 30 30 30 30 65 65 65 65 65Rated short-time withstandcurrent Icw (1s) [kA] 20 20 30 30 30 50 (*) 50 (*) 50 (*) 50 (*) 50 (*) 65 65 65 65 65Rated making capacity undershort-<strong>circuit</strong> (peak value) Icm1000 V [kA] 40 40 63 63 63 105 105 105 105 105 143 143 143 143 1431150 V [kA] 40 40 63 63 63 63 63 63 63 63 143 143 143 143 143(*) 30 kA @ 1150 V.(**) E4H/E and E6H/E are not available in the full-size version.2/6<strong>ABB</strong> SACE

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!