Emax Low voltage air circuit-breakers - ABB Download Center

Emax Low voltage air circuit-breakers - ABB Download Center

Emax Low voltage air circuit-breakers - ABB Download Center

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Primary and secondary distributionSelective protectionSelectivity tables6<strong>Emax</strong> <strong>air</strong> <strong>circuit</strong>-<strong>breakers</strong> with moulded-case <strong>circuit</strong>-<strong>breakers</strong>Supply-side E1 E2 E3 E4 E6Version B N B N S L* N S H V L* S H V H VTrip unit EL EL EL EL ELLoad-side Version Trip unit Size [A] 800 800 1600 1000 800 1250 2500 1000 800 800 2000 4000 3200 3200 4000 32001000 1000 2000 1250 1000 1600 3200 1250 1000 1250 2500 4000 4000 5000 40001250 1250 1600 1250 1600 1250 1600 6300 50001600 1600 2000 1600 2000 1600 2000 63002000 2500 2000 25003200 2500 32003200B T T T T T T T T T T T T T T T TT1 C TM 160 T T T T T T T T T T T T T T T TN T T T T T T T T T T T T T T T TN T T T T T T T T T T T T T T T TT2S 36 T T T T T T T T T T T T T T TTM, EL 160H36 T T 55 65 T T T T T T T T T T TL 36 T T 55 65 T T T 75 T T T T T T TT3 N T T T T T T T T T T T T T T T TTM 250S36 T T T T T T T T T T T T T T TN T T T T T T T T T T T T T T T TT4S 36 T T T T T T T T T T T T T T T250H TM, EL36 T T 55 65 T T T T T T T T T T T320L36 T T 55 65 100 T T 75 85 100 T T 100 T 100V 36 T T 55 65 100 T T 75 85 100 T T 100 T 100N T T T T T T T T T T T T T T T TT5S 36 T T T T T T T T T T T T T T T400H TM, EL36 T T 55 65 T T T T T T T T T T T630L36 T T 55 65 100 T T 75 85 100 T T 100 T 100V 36 T T 55 65 100 T T 75 85 100 T T 100 T 100N T T T T T T T T T T T T T T T TS6S 36 T T T T T T T T T T T T T T TTM, EL 800H36 T T 55 T T T T T T T T T T T TL 36 T T 55 65 T T T 75 85 T T T T T TS7S – – T T T – T T T T T T T T T T1250H EL– – T 55 T – T T T T T T T T T T1600L– – T 55 65 – T T 75 85 T T T T T TGeneral prescriptions:– Function I of the electronic PR121, PR122 and PR123 trip units of the supply-side <strong>circuit</strong>-<strong>breakers</strong> must be excluded (I 3in OFF).– Selectivity is expressed in kA at the supply <strong>voltage</strong> of 380-415 V AC in accordance with IEC 60947-2 Standards.– T = total selectivity (the selectivity value is the lowest one between the breaking capacities (Icu) of both the <strong>circuit</strong>-breaker on the loadsideas well of the <strong>circuit</strong>-breaker on the supply side)– It is of fundamental importance to verify that the settings chosen by the user for the trip units placed both on the supply as well as on the loadside do not result in intersections of the time-current curves for protection against overload (function L) and for protection against short-<strong>circuit</strong>with time-delayed trip (function S).* <strong>Emax</strong> L <strong>circuit</strong>-<strong>breakers</strong> with PR122/P and PR123/P trip units only.6/12<strong>ABB</strong> SACE

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!