12.07.2015 Views

Emax Low voltage air circuit-breakers - ABB Download Center

Emax Low voltage air circuit-breakers - ABB Download Center

Emax Low voltage air circuit-breakers - ABB Download Center

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Switching and protection of capacitorsOperating conditions of <strong>circuit</strong>-<strong>breakers</strong>during continuous service for capacitorbanksAccording to the IEC 60831-1 and 60931-1 Standards, capacitorsmust be able to operate in service conditions with arated rms current of up to 1.3 times the rated current Icn ofthe capacitor. This prescription is due to the possible presenceof harmonics in the mains <strong>voltage</strong>.It should also be kept in mind that a tolerance of +15% isadmissible for the capacitance value corresponding to itsrated power, so that the <strong>circuit</strong>-<strong>breakers</strong> for switching capacitorbanks must be selected to permanently carry a maximumcurrent equal to:ln = 1.3 x 1.15 x lnc = 1.5 x lnc.Current for connecting capacitor banksConnection of a capacitor bank can be compared to a closingoperation under short-<strong>circuit</strong> conditions, where the transientmaking capacity Ip takes on high peak values, above all whencapacitor banks are connected in parallel with others that arealready powered. The value of Ip needs to be calculated foreach individual situation because it depends on the individual<strong>circuit</strong> conditions and can in certain cases even have a peakvalue equal to 100-200 x Icn for a duration of 1-2 ms.This fact must be taken into account when selecting the <strong>circuit</strong>breaker,which must have a suitable making capacity, and whensetting the overcurrent release, which must not cause unwantedtrips when the bank is connected.Selecting the <strong>circuit</strong>-breakerUsing the information on the rating plate of the three-phasecapacitor bankQn = rated power in kvarUn = rated <strong>voltage</strong> in Vthe rated current of the capacitor bank is determined as follows:6Inc =Qn x 10 3, in A.3 x UnThe following conditions must be verified for the <strong>circuit</strong>-breaker:Rated current ln > 1.5 lncOverload protection setting l1 = 1.5 x lncShort-<strong>circuit</strong> protection setting l3 = OFFBreaking capacity lcu > Ik, at the point of installation.<strong>ABB</strong> SACE 6/41

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!