12.07.2015 Views

Emax Low voltage air circuit-breakers - ABB Download Center

Emax Low voltage air circuit-breakers - ABB Download Center

Emax Low voltage air circuit-breakers - ABB Download Center

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Ordering codesSACE <strong>Emax</strong> automatic <strong>circuit</strong>-<strong>breakers</strong>1SDC200260F0001PR121/P PR122/P PR123/P1SDA......R1 1SDA......R1 1SDA......R13 Poles 4 Poles 3 Poles 4 Poles 3 Poles 4 Poles9E3S 16Fixed (F)E3H 16Fixed (F)E3V 16Fixed (F)E3S 20Fixed (F)E3H 20Fixed (F)E3V 20Fixed (F)E3L 20Fixed (F)Icu (415 V) = 75 kA Icw (1 s) = 75 kAHR = Horizontal rear terminalsLI 056208 056216 056211 056219LSI 056209 056217 056212 056220 056214 056222LSIG 056210 056218 056213 056221 056215 056223Icu (415 V) = 100 kA Icw (1 s) = 75 kAHR = Horizontal rear terminalsLI 056400 056408 056403 056411LSI 056401 056409 056404 056412 056406 056414LSIG 056402 056410 056405 056413 056407 056415Icu (415 V) = 130 kA Icw (1 s) = 85 kAHR = Horizontal rear terminalsLI 056592 056600 056595 056603LSI 056593 056601 056596 056604 056598 056606LSIG 056594 056602 056597 056605 056599 056607Icu (415 V) = 75 kA Icw (1 s) = 75 kAHR = Horizontal rear terminalsLI 056240 056248 056243 056251LSI 056241 056249 056244 056252 056246 056254LSIG 056242 056250 056245 056253 056247 056255LSIRc* 058785* to be ordered with toroid for residual current protection (see code on page 9/58)Icu (415 V) = 100 kA Icw (1 s) = 75 kAHR = Horizontal rear terminalsLI 056432 056440 056435 056443LSI 056433 056441 056436 056444 056438 056446LSIG 056434 056442 056437 056445 056439 056447LSIRc* 058713* to be ordered with toroid for residual current protection (see code on page 9/58)Icu (415 V) = 130 kA Icw (1 s) = 85 kAHR = Horizontal rear terminalsLI 056624 056632 056627 056635LSI 056625 056633 056628 056636 056630 056638LSIG 056626 056634 056629 056637 056631 056639LSIRc* 058833* to be ordered with toroid for residual current protection (see code on page 9/58)Icu (415 V) = 130 kA Icw (1 s) = 15 kAHR = Horizontal rear terminalsLI 056720 056728 056723 056731LSI 056721 056729 056724 056732 056726 056734LSIG 056722 056730 056725 056733 056727 056735LSIRc* 058737* to be ordered with toroid for residual current protection (see code on page 9/58)Fixed parts ......................... page 9/51 Terminals ............................ page 9/53 Extra codes ...................... page 9/549/12<strong>ABB</strong> SACE

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!