12.07.2015 Views

High & Ultrahigh Vacuum Thin Film Deposition Technology

High & Ultrahigh Vacuum Thin Film Deposition Technology

High & Ultrahigh Vacuum Thin Film Deposition Technology

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

e-Vap ®Controls and MeasurementSource Control ModuleSource Control ModuleFeatures■ <strong>High</strong> frequency switching technology■ Improved emission stability over 60 Hz SCRcircuits■ Compact filament transformer■ Electrically isolated from high voltage unit■ Grounded and shielded filament transformeroffers improved safety over conventional designs■ Self contained emission current monitoring forindependent operation■ CE compliant■ Full remote control capability■ Touch screen programming■ PS/2 handheld mouse/trackball■ Rack mount brackets included<strong>Thin</strong> <strong>Film</strong> <strong>Deposition</strong>IndirectSpecificationsMeteringDigital Emission CurrentCoolingAir cooledInput power208 V ±10%, Single-phase, 50/60 Hz, 8 AmperesVoltage output12 VACCurrent output0 to 70 AmperesEfficiency 85%Cables From – To LengthInput power cord 1 Wall outlet – Source Control Module 7.5'Interface cable 1 Power Supply – Source Control Module 6'Secondary cable 1 Transformer – e-Vap ® Source 3'Control cable 2 Source Control Module – Transformer 12'Transformer input cable 2 Source Control Module – Transformer 12'<strong>High</strong> voltage cable 2 Power Supply – Transformer 12'WeightDimensionsDirect20 lb8.5" W x 5.25" H x 14" L1 Fixed length cables; not available in other lengths2 A 25-foot cable kit may be purchased separately; three cables are included in one kite-Vap ® CVS Source Control Modules are designed for use withe-Vap ® CVS Series Power Supplies. The source control module unitincludes filament transformer assembly, hand held mouse controland all necessary cables for hook-up with an e-Vap ® CVS PowerSupply. A maximum output current of 70 amperes assures sufficientpower to drive virtually any commercially available electron beamsource. e-Vap ® CVS Source Control Modules are available in threeinstallation packages, direct flange mount and two remote cablemounts. Direct flange mount packages are used on all MDC flangemounted evaporation systems. This package allows mounting of thefilament transformer to a high voltage feedthrough fitted with a2.75" Del-Seal CF flange. Filament transformer attachment isaccomplished by bolting the transformer housing via two of theflanges .250-28 bolts positioned 180° apart. The remote cablemount packages provide 36" of high voltage cable with OFE copperconnector lugs and an acrylic high voltage shield. This package istypically used with modular source installations where high voltageelectrical feedthroughs are fitted with 2-3/4 Del-Seal CF flanges,but limited space does not allow direct installation. The secondremote package is used on installations where high voltage are two1" feedthroughs.The source control module’s compact size occupies only half thewidth in a standard 19" electronics rack. To facilitate the installationinto a standard 19" rack, MDC offers half-rack spacers. However, ifthe source control module is purchased in conjunction with an e-Vap ® programmable X-Y sweep controller the two units can be fastenedtogether to form the standard 19" rack width and would notrequire the half-rack spacer.DESCRIPTIONWEIGHTPOUNDSDIRECT PACKAGE 10REMOTE PACKAGE 10REMOTE FOR 2-1" BOLT FT10HALF RACK SPACER 125-FOOT CABLE KIT 3REFERENCESCM2-DFM-CESCM2-RCM-CESCM2-RCM-1"BEV-HRSSCM-25FC-CEPARTNUMBER991364-01991364991364-02991062991287PRICE$56005750600512585028 Phone 800-443-8817 www.mdcvacuum.com MDC <strong>Vacuum</strong> Products Corporation

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!