Rosemount 3051S Electronic Remote Sensors - Emerson Process ...
Rosemount 3051S Electronic Remote Sensors - Emerson Process ...
Rosemount 3051S Electronic Remote Sensors - Emerson Process ...
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
<strong>Rosemount</strong> <strong>3051S</strong> ERS System<br />
A-36<br />
Reference Manual<br />
00809-0100-4804, Rev AA<br />
January 2011<br />
E1 ATEX Flameproof ★<br />
E2 INMETRO Flameproof ★<br />
E4 TIIS Flameproof ★<br />
E5 FM Explosion-proof, Dust Ignition-proof ★<br />
E6 CSA Explosion-proof, Dust Ignition-proof, Division 2 ★<br />
E7 IECEx Flameproof ★<br />
I1 ATEX Intrinsic Safety ★<br />
I2 INMETRO Intrinsically Safe ★<br />
I5 FM Intrinsically Safe, Division 2 ★<br />
I6 CSA Intrinsically Safe ★<br />
I7 IECEx Intrinsic Safety ★<br />
K1 ATEX Flameproof and Intrinsically Safe, Type n, Dust ★<br />
K2 INMETRO Flameproof, Intrinsic Safety, Type n ★<br />
K5 FM Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2 ★<br />
K6 CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2 ★<br />
K7 IECEx Flameproof, Intrinsic Safety, Type n ★<br />
KA ATEX and CSA Flameproof, Intrinsically Safe, Division 2 ★<br />
KB FM and CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2 ★<br />
KC FM and ATEX Explosion-proof, Intrinsically Safe, Division 2 ★<br />
KD FM, CSA, and ATEX Explosion-proof, Intrinsically Safe, Division 2 ★<br />
N1 ATEX Type n ★<br />
N7 IECEx Type n ★<br />
ND ATEX Dust ★<br />
Digital Display (ERS Primary Configuration Only)<br />
Standard Standard<br />
M5 (1) PlantWeb LCD Display ★<br />
M7 (1) <strong>Remote</strong> Mount LCD Display Interface, PlantWeb Housing, No Cable, SST Bracket ★<br />
M8 (1)<br />
<strong>Remote</strong> Mount LCD Display Interface, PlantWeb Housing, 50 ft. (15.2 m) Cable, SST Bracket ★<br />
M9 (1) Table A-13. <strong>Rosemount</strong> 300 ERS Transmitter Housing Kit Ordering Information<br />
★ The Standard offering represents the most common models and options. These options should be selected for best delivery.<br />
__The Expanded offering is subject to additional delivery lead time.<br />
<strong>Remote</strong> Mount LCD Display Interface, PlantWeb Housing, 100 ft. (30.5 m) Cable, SST Bracket ★<br />
Terminal Block<br />
Standard Standard<br />
T1 Transient Protection ★<br />
(1) Not available with Configuration Type S.