Reference Manual<br />

00809-0100-4804, Rev AA<br />

January 2011<br />

<strong>Rosemount</strong> <strong>3051S</strong> ERS System<br />

Hygienic Tri-Clamp (SC) Seal<br />

• Good for use in hygienic applications<br />

• Easy installation on Tri-Clover style Tri-Clamp connections (1.5-in. to 3-in.)<br />

• Conforms to 3-A standard 74-03<br />

Table A-11. SC Hygienic Tri-Clover Style Tri-Clamp Seal Ordering Information<br />

★ The Standard offering represents the most common models and options. These options should be selected for best delivery.<br />

__The Expanded offering is subject to additional delivery lead time.<br />

<strong>Process</strong> Connection<br />

Standard Standard<br />

SC (1) Tri-Clover Style Tri-Clamp Seal ★<br />

<strong>Process</strong> Connection Size<br />

Standard Standard<br />

3 (2) 1½ in. ★<br />

5 (2) 2 in. ★<br />

7 3 in. ★<br />

Maximum Working Pressure<br />

Standard Standard<br />

0 1000 PSI ★<br />

Isolating Diaphragm Material Upper Housing Material<br />

Standard Standard<br />

LA00<br />

Expanded<br />

316L SST 316L SST ★<br />

LB00 Alloy C-276 316L SST<br />

Options (Include with selected model number)<br />

Diaphragm Surface Finish and Polishing<br />

Expanded<br />

R6 Electropolishing<br />

RD 10 �in. (0.25 �m) Ra Diaphragm Surface Finish<br />

RG 15 �in. (0.375 �m) Ra Diaphragm Surface Finish<br />

RH 20 �in. (0.5 �m) Ra Diaphragm Surface Finish<br />

Certifications<br />

Standard Standard<br />

Q16 Surface Finish Certification ★<br />

Complete the <strong>3051S</strong>AL model number by specifying options as needed:<br />

page A-24 ERS Transmitter Options<br />

(1) Clamp and gasket furnished by user. The maximum working pressure is dependent upon the clamp pressure rating.<br />

(2) Consult factory for calibrated spans lower than 5 psi (345 mbar).<br />