Rosemount 3051S Electronic Remote Sensors - Emerson Process ...
Rosemount 3051S Electronic Remote Sensors - Emerson Process ...
Rosemount 3051S Electronic Remote Sensors - Emerson Process ...
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
<strong>Rosemount</strong> <strong>3051S</strong> ERS System<br />
A-6<br />
Power Supply<br />
External power supply required (16 – 42.4 Vdc with no load)<br />
Reference Manual<br />
00809-0100-4804, Rev AA<br />
January 2011<br />
Load Limitations<br />
Maximum loop resistance is determined by the voltage level of the external<br />
power supply:<br />
• If supply voltage ≤ 16.74 Vdc, Maximum Loop Resistance = 277.8 *<br />
(Power Supply Voltage – 16.0)<br />
• If supply voltage > 16.74 Vdc, Maximum Loop Resistance = 43.5 *<br />
(Power Supply Voltage – 12.0)<br />
1322<br />
Load (Ohms)<br />
206<br />
Burst Pressure Limits<br />
• Coplanar Gage / Absolute Sensor Module (<strong>3051S</strong>AM_ _G,<br />
<strong>3051S</strong>AM_ _A): 10000 psi (689,5 bar)<br />
• In-Line Gage / Absolute Sensor Module (<strong>3051S</strong>AM_ _T,<br />
<strong>3051S</strong>AM_ _E)<br />
• Ranges 1-4: 11000 psi (758,4 bar)<br />
• Range 5: 26000 psi (1792,64 bar)<br />
Ambient Temperature Limits<br />
0<br />
Operating<br />
Region<br />
16 16.74 42.4<br />
Voltage (Vdc)<br />
Overpressure Limits (1)<br />
<strong>3051S</strong> ERS sensor modules can withstand the following limits without damage<br />
Coplanar Gage Sensor<br />
(<strong>3051S</strong>AM_ _G)<br />
Coplanar Absolute Sensor<br />
(<strong>3051S</strong>AM_ _A)<br />
In-Line Gage Sensor<br />
(<strong>3051S</strong>AM_ _T)<br />
During Operation<br />
• -40 to 185 °F (-40 to 85 °C)<br />
• With LCD display (1) : -40 to 175 °F (-40 to 80 °C)<br />
In-Line Absolute Sensor<br />
(<strong>3051S</strong>AM_ _E)<br />
Range 1 N/A 750 psia (51,7 bar) 750 psia (51,7 bar) 750 psia (51,7 bar)<br />
Range 2 3626 psi (250 bar) 1500 psia (103,4 bar) 1500 psia (103,4 bar) 1500 psia (103,4 bar)<br />
Range 3 3626 psi (250 bar) 1600 psia (110,3 bar) 1600 psia (110,3 bar) 1600 psia (110,3 bar)<br />
Range 4 3626 psi (250 bar) 6000 psia (413,7 bar) 6000 psia (413,7 bar) 6000 psia (413,7 bar)<br />
Range 5 3626 psi (250 bar) N/A 15000 psig (1034,2 bar) 15000 psig (1034,2 bar)<br />
(1) The overpressure limit for configurations with remote seals (including <strong>3051S</strong>AL) is dependent on the flange rating or sensor rating (whichever is lower).<br />
Use Instrument Toolkit to ensure the seal system meets all pressure and temperature limits.<br />
(1) LCD display may not be readable, and LCD updates will be slower at temperatures below -4 °F (-20 °C)