01.12.2012 Views

Rosemount 3051S Electronic Remote Sensors - Emerson Process ...

Rosemount 3051S Electronic Remote Sensors - Emerson Process ...

Rosemount 3051S Electronic Remote Sensors - Emerson Process ...

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Reference Manual<br />

00809-0100-4804, Rev AA<br />

January 2011<br />

<strong>Rosemount</strong> <strong>3051S</strong> ERS System<br />

I5 FM Intrinsically Safe, Division 2 ★<br />

K5 FM Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2 ★<br />

E6 (3)<br />

CSA Explosion-proof, Dust Ignition-proof, Division 2 ★<br />

I6 CSA Intrinsically Safe ★<br />

K6 (3) CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2 ★<br />

E7 IECEx Flameproof ★<br />

I7 IECEx Intrinsic Safety ★<br />

N7 IECEx Type n ★<br />

K7 IECEx Flameproof, Intrinsic Safety, Type n ★<br />

E2 INMETRO Flameproof ★<br />

I2 INMETRO Intrinsically Safe ★<br />

K2 INMETRO Flameproof, Intrinsic Safety, Type n ★<br />

KA (3) ATEX and CSA Flameproof, Intrinsically Safe, Division 2 ★<br />

KB (3) FM and CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2 ★<br />

KC FM and ATEX Explosion-proof, Intrinsically Safe, Division 2 ★<br />

KD (3) FM, CSA, and ATEX Explosion-proof, Intrinsically Safe ★<br />

Alternate Materials of Construction<br />

Standard Standard<br />

L1 (4) Inert Sensor Fill Fluid ★<br />

L2 Graphite-Filled PTFE O-Ring ★<br />

L4 Austenitic 316 SST Bolts ★<br />

L5 (5) ASTM A 193, Grade B7M Bolts ★<br />

L6 Alloy K-500 Bolts ★<br />

L7 (5)<br />

ASTM A 453, Class D, Grade 660 Bolts ★<br />

L8 ASTM A 193, Class 2, Grade B8M Bolts ★<br />

Display Type (ERS Primary Only)<br />

Standard Standard<br />

M5 (2) PlantWeb LCD Display ★<br />

M7 (2) <strong>Remote</strong> Mount LCD Display and Interface, PlantWeb Housing, No Cable, SST Bracket ★<br />

M8 (2)<br />

<strong>Remote</strong> Mount LCD Display and Interface, PlantWeb Housing, 50 ft. (15.2 m) Cable, SST Bracket ★<br />

M9 (2) <strong>Remote</strong> Mount LCD Display and Interface, PlantWeb Housing, 100 ft. (30.5 m) Cable, SST Bracket ★<br />

Special Procedures<br />

Expanded<br />

P1 Hydrostatic Testing with Certificate<br />

P2 Cleaning for Special Services<br />

P3 Cleaning for Less than 1 PPM Chlorine/Fluorine<br />

Special Certifications<br />

Standard Standard<br />

Q4 Calibration Certificate ★<br />

QP Calibration certificate with tamper evident seal ★<br />

Q8 Material traceability certification per EN 10204 3.1 ★<br />

QZ (6)<br />

<strong>Remote</strong> Seal System Performance Calculation Report ★<br />

Transient Protection<br />

Standard Standard<br />

T1 (2)<br />

Transient Terminal Block ★<br />

Typical Model Number: <strong>3051S</strong>AL 1 P G 4A A 1A 1 0 20 D FF 7 1 DA 0 0 M5<br />

(1) The pressure range should be specified based on the maximum static pressure, not differential pressure.<br />

(2) Not available with Configuration Type code S.<br />

(3) Not available with M20 or G ½ conduit entry size.<br />

(4) Silicone fill fluid is standard.<br />

(5) Materials of construction comply with metallurgical requirements highlighted within NACE MR0175 / ISO 15156 for sour oil field production environments.<br />

Environmental limits apply to certain materials. Consult latest standard for details. Selected materials also conform to NACE MR0103 for sour refining<br />

environments.<br />

(6) The QZ report quantifies the performance of the entire ERS system. One report is provided per ERS system. The QZ option is specified on the Primary<br />

Transmitter (Configuration Type code P).<br />

A-25