<strong>Rosemount</strong> <strong>3051S</strong> ERS System<br />
Continue specifying a completed model number by choosing a remote seal type below:<br />
A-24<br />
page A-26 FF Flush Flanged Seal <strong>Process</strong> Connections:<br />
2 in. / DN 50<br />
3 in. / DN 80<br />
4 in. / DN 100<br />
page A-28 EF Extended Flanged Seal <strong>Process</strong> Connections:<br />
3 in. / DN 80<br />
4 in. / DN 100<br />
page A-29 RF <strong>Remote</strong> Flanged Seal <strong>Process</strong> Connections:<br />
1 in. / DN 25<br />
1.5 in. / DN 40<br />
page A-31 RT <strong>Remote</strong> Threaded Seal <strong>Process</strong> Connections:<br />
¼ - 18 NPT<br />
½ - 14 NPT<br />
¾ - 14 NPT<br />
1 – 11.5 NPT<br />
page A-33 SC Hygienic Tri-Clamp Seal <strong>Process</strong> Connections:<br />
1.5 in.<br />
2 in.<br />
3 in.<br />
page A-34 SS Hygienic Tank Spud Seal <strong>Process</strong> Connections:<br />
4 in.<br />
Reference Manual<br />
00809-0100-4804, Rev AA<br />
January 2011<br />
Options (Include with selected model number)<br />
<strong>Electronic</strong> <strong>Remote</strong> Sensor Connection Cable<br />
Standard (1) Standard<br />
R05 50 ft. (15.2 m) Spool of <strong>Electronic</strong> <strong>Remote</strong> Sensor Cable ★<br />
R10 100 ft. (30.5 m) Spool of <strong>Electronic</strong> <strong>Remote</strong> Sensor Cable ★<br />
Special Configuration (Software)<br />
Standard Standard<br />
C1 (2) Customer Software Configuration (“Configuration Data Sheet” Must Be Completed) ★<br />
C3 Gage Pressure Calibration on <strong>Rosemount</strong> <strong>3051S</strong>AL_ _A4 only ★<br />
C4 (2)<br />
NAMUR Alarm and Saturation Levels, High Alarm ★<br />
C5 (2)<br />
NAMUR Alarm and Saturation Levels, Low Alarm ★<br />
C6 (2) Custom Alarm and Saturation Levels, High Alarm (Requires C1 and Configuration Data Sheet) ★<br />
C7 (2) Custom Alarm and Saturation Levels, Low Alarm (Requires C1 and Configuration Data Sheet) ★<br />
C8 (2)<br />
Low Alarm (Standard <strong>Rosemount</strong> Alarm and Saturation Levels) ★<br />
Special Configuration (Hardware)<br />
Standard Standard<br />
D4 External Ground Screw Assembly ★<br />
Product Certifications<br />
Standard Standard<br />
E1 ATEX Flameproof ★<br />
I1 ATEX Intrinsic Safety ★<br />
N1 ATEX Type n ★<br />
K1 ATEX Flameproof and Intrinsically Safe, Type n, Dust ★<br />
ND ATEX Dust ★<br />
E4 TIIS Flameproof ★<br />
E5 FM Explosion-proof, Dust Ignition-proof ★