<strong>Rosemount</strong> <strong>3051S</strong> ERS System<br />

Continue specifying a completed model number by choosing a remote seal type below:<br />

A-24<br />

page A-26 FF Flush Flanged Seal <strong>Process</strong> Connections:<br />

2 in. / DN 50<br />

3 in. / DN 80<br />

4 in. / DN 100<br />

page A-28 EF Extended Flanged Seal <strong>Process</strong> Connections:<br />

3 in. / DN 80<br />

4 in. / DN 100<br />

page A-29 RF <strong>Remote</strong> Flanged Seal <strong>Process</strong> Connections:<br />

1 in. / DN 25<br />

1.5 in. / DN 40<br />

page A-31 RT <strong>Remote</strong> Threaded Seal <strong>Process</strong> Connections:<br />

¼ - 18 NPT<br />

½ - 14 NPT<br />

¾ - 14 NPT<br />

1 – 11.5 NPT<br />

page A-33 SC Hygienic Tri-Clamp Seal <strong>Process</strong> Connections:<br />

1.5 in.<br />

2 in.<br />

3 in.<br />

page A-34 SS Hygienic Tank Spud Seal <strong>Process</strong> Connections:<br />

4 in.<br />

Reference Manual<br />

00809-0100-4804, Rev AA<br />

January 2011<br />

Options (Include with selected model number)<br />

<strong>Electronic</strong> <strong>Remote</strong> Sensor Connection Cable<br />

Standard (1) Standard<br />

R05 50 ft. (15.2 m) Spool of <strong>Electronic</strong> <strong>Remote</strong> Sensor Cable ★<br />

R10 100 ft. (30.5 m) Spool of <strong>Electronic</strong> <strong>Remote</strong> Sensor Cable ★<br />

Special Configuration (Software)<br />

Standard Standard<br />

C1 (2) Customer Software Configuration (“Configuration Data Sheet” Must Be Completed) ★<br />

C3 Gage Pressure Calibration on <strong>Rosemount</strong> <strong>3051S</strong>AL_ _A4 only ★<br />

C4 (2)<br />

NAMUR Alarm and Saturation Levels, High Alarm ★<br />

C5 (2)<br />

NAMUR Alarm and Saturation Levels, Low Alarm ★<br />

C6 (2) Custom Alarm and Saturation Levels, High Alarm (Requires C1 and Configuration Data Sheet) ★<br />

C7 (2) Custom Alarm and Saturation Levels, Low Alarm (Requires C1 and Configuration Data Sheet) ★<br />

C8 (2)<br />

Low Alarm (Standard <strong>Rosemount</strong> Alarm and Saturation Levels) ★<br />

Special Configuration (Hardware)<br />

Standard Standard<br />

D4 External Ground Screw Assembly ★<br />

Product Certifications<br />

Standard Standard<br />

E1 ATEX Flameproof ★<br />

I1 ATEX Intrinsic Safety ★<br />

N1 ATEX Type n ★<br />

K1 ATEX Flameproof and Intrinsically Safe, Type n, Dust ★<br />

ND ATEX Dust ★<br />

E4 TIIS Flameproof ★<br />

E5 FM Explosion-proof, Dust Ignition-proof ★