<strong>Rosemount</strong> <strong>3051S</strong> ERS System<br />

Table A-2. Gage / Absolute Pressure Reference Accuracy<br />

Coplanar Gage Sensor (<strong>3051S</strong>AM_ _G)<br />

Ultra Classic<br />

Range 2-4 ±0.025% of span<br />

±0.055% of span<br />

Range 5 ±0.05% of span<br />

A-2<br />

For spans less than 10:1,<br />

±[0.005 + 0.0035(URL / Span)] % of span<br />

For spans less than 10:1,<br />

±[0.005 + 0.0045(URL / Span)] % of span<br />

Coplanar Absolute Sensor (<strong>3051S</strong>AM_ _A)<br />

Ultra Classic<br />

Ranges 1-4 ±0.025% of span<br />

±0.055% of span<br />

For spans less than 10:1,<br />

±[0.015 + 0.005(URL / Span)] % of span<br />

±0.065% of span<br />

For spans less than 10:1,<br />

±[0.015 + 0.005(URL / Span)] % of span<br />

For spans less than 10:1,<br />

±[0.004(URL / Span)] % of span<br />

In-Line Gage Sensor (<strong>3051S</strong>AM_ _T)<br />

In-Line Absolute Sensor (<strong>3051S</strong>AM _ _E)<br />

For spans less than 10:1,<br />

±[0.0065(URL / Span)] % of span<br />

Ultra Classic<br />

Ranges 1-4 ±0.025% of span<br />

±0.055% of span<br />

Ranges 5 ±0.04% of span<br />

For spans less than 10:1,<br />

±[0.004(URL / Span)] % of span<br />

For spans less than 10:1,<br />

±[0.0065(URL / Span)] % of span<br />

±0.065% of span<br />

For spans less than 10:1,<br />

±[0.004(URL / Span)] % of span<br />

Liquid Level Sensor (<strong>3051S</strong>AL)<br />

For spans less than 10:1,<br />

±[0.0065(URL / Span)] % of span<br />

Ultra Classic<br />

Ranges 1-5 ±0.065% of span<br />

±0.065% of span<br />

For spans less than 10:1,<br />

±[0.015 + 0.005(URL / Span)] % of span<br />

For spans less than 10:1,<br />

±[0.015 + 0.005(URL / Span)] % of span<br />

Reference Manual<br />

00809-0100-4804, Rev AA<br />

January 2011<br />

Long Term Stability (1)<br />

Gage / Absolute “Ultra” Sensor Gage / Absolute “Classic” Sensor<br />

±0.20% of URL for 10 years; for ±50 °F (28 °C) temperature ±0.125% of URL for 5 years; for ±50 °F (28 °C) temperature<br />

changes, up to 1000 psi (68,9 bar) line pressure<br />

changes, up to 1000 psi (68,9 bar) line pressure<br />

(1) Long term stability specification is for each gage / absolute pressure sensor of the ERS System and is not reflective of the DP calculation.<br />

Warranty (1)<br />

Gage / Absolute “Ultra” Sensor Gage / Absolute “Classic” Sensor<br />

12-year limited warranty (2) 1-year limited warranty (3)<br />

(1) Warranty details can be found in <strong>Emerson</strong> <strong>Process</strong> Management Terms & Conditions of Sale, Document 63445, Rev G (10/06).<br />

(2) <strong>Rosemount</strong> Ultra sensors in an ERS configuration have a limited warranty of twelve (12) years from date of shipment. All other provisions of<br />

<strong>Emerson</strong> <strong>Process</strong> Management standard limited warranty remain the same.<br />

(3) Goods are warranted for twelve (12) months from the date of initial installation or eighteen (18) months from the date of shipment by seller,<br />

whichever period expires first.