01.12.2012 Views

Rosemount 3051S Electronic Remote Sensors - Emerson Process ...

Rosemount 3051S Electronic Remote Sensors - Emerson Process ...

Rosemount 3051S Electronic Remote Sensors - Emerson Process ...

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Reference Manual<br />

00809-0100-4804, Rev AA<br />

January 2011 <strong>Rosemount</strong> <strong>3051S</strong> ERS System<br />

Appendix A Specifications and<br />

Reference Data<br />

PERFORMANCE<br />

SPECIFICATIONS<br />

Conformance to<br />

Specification (±3�)<br />

Reference Accuracy<br />

Table A-1. DP Reference Accuracy of <strong>3051S</strong> ERS System (1)<br />

Two Coplanar Gage <strong>Sensors</strong> (<strong>3051S</strong>AM_ _G)<br />

www.rosemount.com<br />

Performance Specifications . . . . . . . . . . . . . . . . . . . . . . . page A-1<br />

Functional Specifications . . . . . . . . . . . . . . . . . . . . . . . . . page A-4<br />

Physical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . page A-9<br />

Dimensional Drawings . . . . . . . . . . . . . . . . . . . . . . . . . . . . page A-11<br />

Ordering Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page A-17<br />

Spare Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page A-37<br />

For zero-based spans, reference conditions, silicone oil fill, glass-filled PTFE<br />

o-rings, SST materials, Coplanar flange, or 1 /2 in.-14 NPT process<br />

connections, digital trim values are set to equal range points.<br />

Technology leadership, advanced manufacturing techniques, and statistical<br />

process control ensure specification conformance to at least ±3�.<br />

Ultra Classic<br />

Range 2-4 ±0.035% of DP span ±0.078% of DP span<br />

Range 5 ±0.071% of DP span ±0.092% of DP span<br />

Two Coplanar Absolute <strong>Sensors</strong> (<strong>3051S</strong>AM_ _A)<br />

Ultra Classic<br />

Ranges 1-4 ±0.035% of DP span ±0.078% of DP span<br />

Two In-Line Gage <strong>Sensors</strong> (<strong>3051S</strong>AM_ _T)<br />

Two In-Line Absolute <strong>Sensors</strong> (<strong>3051S</strong>AM _ _E)<br />

Ultra Classic<br />

Ranges 1-4 ±0.035% of DP span ±0.078% of DP span<br />

Two Liquid Level <strong>Sensors</strong> (<strong>3051S</strong>AL)<br />

Ultra Classic<br />

Ranges 1-5 ±0.092% of DP span ±0.092% of DP span<br />

(1) DP Accuracy specifications for the <strong>3051S</strong> ERS System assume that the configuration contains two sensors with identical ranges that are calibrated<br />