01.12.2012 Views

Rosemount 3051S Electronic Remote Sensors - Emerson Process ...

Rosemount 3051S Electronic Remote Sensors - Emerson Process ...

Rosemount 3051S Electronic Remote Sensors - Emerson Process ...

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Rosemount</strong> <strong>3051S</strong> ERS System<br />

A-22<br />

Reference Manual<br />

00809-0100-4804, Rev AA<br />

January 2011<br />

<strong>Rosemount</strong> <strong>3051S</strong>AL Level Transmitter for ERS Applications<br />

• Integrated transmitter and remote seal in a single model number<br />

• Variety of process connections including flanged, threaded, and hygienic remote seals<br />

• Available with 10-year stability and limited 12-year warranty<br />

A <strong>3051S</strong>AL Transmitter consists of 3 parts. First, specify the transmitter model codes found on page A-22. Then,<br />

specify a remote seal found on page A-26. Finish the model number by specifying all desired options on<br />

page A-24.<br />

ERS Transmitter Model Codes page A-22 <strong>Remote</strong> Seal Model Codes____ page A-26 ERS Options______page A-24<br />

Table A-6. <strong>3051S</strong>AL Scalable Advanced Level Transmitter for ERS Applications Ordering Information<br />

★ The Standard offering represents the most common models and options. These options should be selected for best delivery.<br />

__The Expanded offering is subject to additional delivery lead time.<br />

Model Transmitter Type<br />

<strong>3051S</strong>AL Scalable Advanced Level Transmitter<br />

Performance Class<br />

Standard Standard<br />

1 Ultra: 0.025% span accuracy, 200:1 rangedown, 10-year stability, 12-year limited warranty ★<br />

2 Classic: 0.055% span accuracy, 100:1 rangedown, 5-year stability ★<br />

Configuration Type<br />

Standard Standard<br />

P <strong>Electronic</strong> <strong>Remote</strong> Sensor - Primary ★<br />

S <strong>Electronic</strong> <strong>Remote</strong> Sensor - Secondary ★<br />

Pressure Module Type Pressure Sensor Type<br />

Standard Standard<br />

G Coplanar Gage ★<br />

T In-Line Gage ★<br />

E<br />

Expanded<br />

In-Line Absolute ★<br />

A Coplanar Absolute<br />

Pressure Range (1)<br />

Coplanar Gage Coplanar Absolute In-Line Gage In-Line Absolute<br />

Standard Standard<br />

1A N/A 0 to 30 psia<br />

-14.7 to 30 psig<br />

0 to 30 psia<br />

★<br />

(0 to 2,06 bar)<br />

(-1,0 to 2,06 bar) (0 to 2,06 bar)<br />

2A -250 to 250 inH2O<br />

0 to 150 psia<br />

-14.7 to 150 psig 0 to 150 psia<br />

★<br />

(-623 to 623 mbar)<br />

(0 to 10,34 bar)<br />

(-1,0 to 10,34 bar) (0 to 10,34 bar)<br />

3A -393 to 1000 inH2O 0 to 800 psia<br />

-14.7 to 800 psig 0 to 800 psia<br />

★<br />

(-0,98 to 2,49 bar)<br />

(0 to 55,2 bar)<br />

(-1,0 to 55,2 bar) (0 to 55,2 bar)<br />

4A -14.2 to 300 psig<br />

0 to 4000 psia<br />

-14.7 to 4000 psig 0 to 4000 psia<br />

★<br />

(-0,98 to 20,7 bar)<br />

(0 to 275,8 bar)<br />

(-1,0 to 275,8 bar) (0 to 275,8 bar)<br />

5A -14.2 to 2000 psig<br />

(-0,98 to 137,9 bar)<br />

N/A -14.7 to 10000 psig<br />

(-1,0 to 689,5 bar)<br />

0 to 10000 psia<br />

(0 to 689 bar)<br />

Transmitter Output<br />

Standard Standard<br />

A 4-20 mA with Digital Signal Based on HART Protocol ★<br />

Housing Style Material Conduit Entry Size<br />

Standard Standard<br />