<strong>Rosemount</strong> <strong>3051S</strong> ERS System<br />
A-22<br />
Reference Manual<br />
00809-0100-4804, Rev AA<br />
January 2011<br />
<strong>Rosemount</strong> <strong>3051S</strong>AL Level Transmitter for ERS Applications<br />
• Integrated transmitter and remote seal in a single model number<br />
• Variety of process connections including flanged, threaded, and hygienic remote seals<br />
• Available with 10-year stability and limited 12-year warranty<br />
A <strong>3051S</strong>AL Transmitter consists of 3 parts. First, specify the transmitter model codes found on page A-22. Then,<br />
specify a remote seal found on page A-26. Finish the model number by specifying all desired options on<br />
page A-24.<br />
ERS Transmitter Model Codes page A-22 <strong>Remote</strong> Seal Model Codes____ page A-26 ERS Options______page A-24<br />
Table A-6. <strong>3051S</strong>AL Scalable Advanced Level Transmitter for ERS Applications Ordering Information<br />
★ The Standard offering represents the most common models and options. These options should be selected for best delivery.<br />
__The Expanded offering is subject to additional delivery lead time.<br />
Model Transmitter Type<br />
<strong>3051S</strong>AL Scalable Advanced Level Transmitter<br />
Performance Class<br />
Standard Standard<br />
1 Ultra: 0.025% span accuracy, 200:1 rangedown, 10-year stability, 12-year limited warranty ★<br />
2 Classic: 0.055% span accuracy, 100:1 rangedown, 5-year stability ★<br />
Configuration Type<br />
Standard Standard<br />
P <strong>Electronic</strong> <strong>Remote</strong> Sensor - Primary ★<br />
S <strong>Electronic</strong> <strong>Remote</strong> Sensor - Secondary ★<br />
Pressure Module Type Pressure Sensor Type<br />
Standard Standard<br />
G Coplanar Gage ★<br />
T In-Line Gage ★<br />
E<br />
Expanded<br />
In-Line Absolute ★<br />
A Coplanar Absolute<br />
Pressure Range (1)<br />
Coplanar Gage Coplanar Absolute In-Line Gage In-Line Absolute<br />
Standard Standard<br />
1A N/A 0 to 30 psia<br />
-14.7 to 30 psig<br />
0 to 30 psia<br />
★<br />
(0 to 2,06 bar)<br />
(-1,0 to 2,06 bar) (0 to 2,06 bar)<br />
2A -250 to 250 inH2O<br />
0 to 150 psia<br />
-14.7 to 150 psig 0 to 150 psia<br />
★<br />
(-623 to 623 mbar)<br />
(0 to 10,34 bar)<br />
(-1,0 to 10,34 bar) (0 to 10,34 bar)<br />
3A -393 to 1000 inH2O 0 to 800 psia<br />
-14.7 to 800 psig 0 to 800 psia<br />
★<br />
(-0,98 to 2,49 bar)<br />
(0 to 55,2 bar)<br />
(-1,0 to 55,2 bar) (0 to 55,2 bar)<br />
4A -14.2 to 300 psig<br />
0 to 4000 psia<br />
-14.7 to 4000 psig 0 to 4000 psia<br />
★<br />
(-0,98 to 20,7 bar)<br />
(0 to 275,8 bar)<br />
(-1,0 to 275,8 bar) (0 to 275,8 bar)<br />
5A -14.2 to 2000 psig<br />
(-0,98 to 137,9 bar)<br />
N/A -14.7 to 10000 psig<br />
(-1,0 to 689,5 bar)<br />
0 to 10000 psia<br />
(0 to 689 bar)<br />
Transmitter Output<br />
Standard Standard<br />
A 4-20 mA with Digital Signal Based on HART Protocol ★<br />
Housing Style Material Conduit Entry Size<br />
Standard Standard<br />
★