<strong>CUVX</strong> <strong>Design</strong> – VT Team 2 Page 65Endurance Fuel CalculationCalculate <strong>the</strong> required fuel tank volume for specified endurance range and average 24 hour electric load.Fuel Tankagelton 2240. lbf δ F 43.6. ft3δ AF 42. ft3 δ LO 39. ft3 δ W 36.ft3ltonltonltonltonAverage endurance brake horsepower required with 10% margin for fouling and sea state:P eBAVG BHP e P eBAVG = 3.069. 10 4 hp E = 4. 10 3 nm V e = 20 kntCorrection for instrumentation inaccuracy and machinery design changes:f 111.04 if P .BPENGe3 P BPENGrated f 1 = 1.0221.02 if P .BPENGe3 P BPENGrated1.03 o<strong>the</strong>rwiseSpecified fuel rate: FR SP f . 1 SFC ePEratedkgFR SP = 0.216kW.hrAverage fuel rate allowing for plant deterioration over 2 years: FR AVG 1.05. FR . SP g FR AVG 2.264. 10 4 MT=kW.hrEBurnable propulsion endurance fuel weight: W . BP P . eBAVG FR AVGV eW BP = 1.036. 10 3 MTTailpipe allowance: TPA 0.95W BPRequired propulsion endurance fuel load (weight): W FPTPAW FP = 1.091. 10 3 MTRequired propulsion fuel tank volume (including allowance for expansion, 5%, and tank internal structure, 2%):V FP 1.02. 1.05. W . FP δ FV FP = 1.42. 10 3 m 3 (for 200 hours of propulsion - endurance range)Average 24 hour electrical load for <strong>the</strong> ship service diesel generatorsKW 24AVG 4569 kW N GENAVG 2P GENAVGPMF . e KW 24AVGP GENAVG = 3.37. 10 3 hp SFC GE 0.62. lbf (from MEN, Ch. 6, Figure 10)N GENAVG hp . hrMargin for instrumentation inaccuracy and machinery design changes: f 1e 1.04Specified fuel rate: FR GSP f . 1e SFC GEAverage fuel rate, allowing for plant deterioration: FR GAVG 1.05. FR GSPFR GAVG 3.07110 . 4 MT=hp . hrEBurnable electrical endurance fuel weight: W . Be KW . 24AVG FR GAVGV W e Be = 376.329 MTW BeRequired electrical fuel weight: W FeTPAW Fe = 396.135 MTRequired electrical fuel volume: V Fe 1.02. 1.05. δ . F W FeV Fe = 515.526m 3Total fuel weight and tanks volume: W F41 W FP W Fe W F41 = 1.487. 10 3 MTV F V FP V Fe V F = 1.93510 . 3 m 3Hour 8 (number of hours of fuel required in tanks)total tankage required for endurance speedand range with 24 average electrical loadV FP V FeV FuelServiceTank200 248 8V FuelServiceTank = 228.632m 3total required capacity for fuel service tank located in <strong>the</strong> MMR'sV FuelServiceTank= 76.211m 3 per tank (1 in each MMR)3O<strong>the</strong>r TanksN T 898 N A 90 (Total crew size and total accomodations) BAL TYP 1Aircraft fuel: W F42 1503. MTV AF 1.02. 1.05. W . F42 δ AFV AF = 1.88410 . 3 m 3Lubrication oil: W F46 17.6. ltonV LO 1.02. 1.05. W . F46 δ LOV LO = 20.817m 3Potable water: (Water does not expand). W F52 N . T 0.45. ltonW F52 = 410.585 MTV W1.02. W . F52 δ WV W = 420.181m 3Sewage: V SEW N T N . A 2.005. ft 3V SEW = 56.094m 3Waste oil: V WASTE 0.02. V FV WASTE = 38.705m 3Clean ballast: (compensated ballast) V BAL if BAL TYP 1, 0.19.V F , 0.275V . F V BAL = 367.7 m 3Total tankage volume required: V TK V F V AF V LO V W V SEW V WASTE V BAL V TK 4.72310 3 . m 3=Figure 57. Endurance Fuel Calculation

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!