01.12.2012 Views

Master Thesis - Fachbereich Informatik

Master Thesis - Fachbereich Informatik

Master Thesis - Fachbereich Informatik

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

5.1. EXPERIMENTAL DESIGN 103<br />

Ground Truth Length [mm]<br />

52.5<br />

52<br />

51.5<br />

51<br />

50.5<br />

50<br />

49.5<br />

49<br />

48.5<br />

Intra Human Variance<br />

48<br />

0 2 4 6 8 10 12 14<br />

Tube<br />

(a)<br />

Ground Truth Length [mm]<br />

52.5<br />

52<br />

51.5<br />

51<br />

50.5<br />

50<br />

49.5<br />

49<br />

48.5<br />

Inter Human Variance<br />

48<br />

0 2 4 6 8 10 12 14<br />

Tube<br />

Figure 5.2: Intra and inter human variance for the test set in Table 5.3 under ideal laboratory<br />

conditions. The error bars indicate the maximum and minimum length for each of the 12 tubes<br />

as well as the mean value of the measurements once for one person (a) and once for 10 persons<br />

(b). The average inter human variance is slightly larger compared to the intra human variance.<br />

Theerrorbarsindicatethemaximumandminimumlengthaswellasthemeanvalueof<br />

all measurements. The computed mean standard deviation is 0.078mm.<br />

In a second experiment, the inter human variance is determined. Therefore, 10 persons<br />

have been asked to measure the same test set again as precise as possible. The inter human<br />

variance is slightly larger than the intra human variance (see Figure 5.2(b)). In this case,<br />

the mean standard deviation was observed to be 0.083mm.<br />

Furthermore, it is important to state that the manual measurements for the ground<br />

truth data have been acquired very carefully with elevated concentration under laboratory<br />

conditions and with the aim to be as precise as possible using the digital measuring slide<br />

(see Figure 5.1). Less than 5 tubes can be measured within one minute at this precision. At<br />

production, the sample measurements are performed with a standard sliding caliper and<br />

at a much higher rate. There is a definitively tradeoff between accuracy and speed. The<br />

expected individual measuring error at production is much larger. Furthermore, factors<br />

like tiredness or distraction can significantly increase the inter and intra human measuring<br />

variance.<br />

The accuracy and precision of the visual inspection system, however, should be evaluated<br />

with respect to the maximum possible accuracy humans can reach with the given<br />

measuring slide under ideal conditions. Throughout this thesis, manual ground truth measurements<br />

always refer to the ideal, laboratory condition measurements. One has to keep<br />

in mind that there is still a certain unsureness in these measurements. The real absolute<br />

length of a tube can not be determined exactly.<br />

For the following experiments, all tubes have been measured three times to reduce the<br />

influence of the human variance. The mean of the three measurements is taken as ground<br />

truth reference. All measurements are stored in a database and each measured tube is<br />

labeled by hand with a four digit ID using a white touch-up pen.<br />

(b)

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!