12.07.2015 Views

Vashon (Avanti DVS FS) - Avalon

Vashon (Avanti DVS FS) - Avalon

Vashon (Avanti DVS FS) - Avalon

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

26 Safety LabelThe listing label is shown below for your records. It can be found on the back panel.Tested &Listed byRTM<strong>Avanti</strong> <strong>DVS</strong> <strong>FS</strong>Listed Gas-FiredDirect Vent Wall FurnaceCertified for USA & CanadaTested to: ANSI Z21.44-1995 Gas-Fired Gravity and Fan type Direct-Vent Wall Furnace, and applicable sections of ANSI Z21.11.1a-1993 Gas-FiredVented Room Heaters. CAN 1-2.19-M81 Gas-Fired Direct-Vent Wall Furnace, CAN/CGA 2.17-M91 “Gas-Fired Appliances for use at High Altitudes”,UL307b-1995 “Gas Burning Heating Appliances for Manufactured Homes”, and ANSI Z21.50-1996/CGA-2.22-M96 Vented Gas Fireplaces.Must be installed in accordance with the manufacturer’s installation instructions and all local codes, if any; if not, follow current ANSI Z223.1,NFPA 54 and CGA B149. In Manufactured or Mobile Homes this appliance must be installed to the applicable Mobile Home Standards: CAN/CSAZ240 MH, the Manufactured Home Construction and Safety Standard, Title 24 CFR, Criteria for Manufactured Home Installations, Sites andCommunities, and/or ANSI/NFPA 501A. This appliance is designed to operate on natural gas, or propane (LP). This appliance uses a millivolt-typecontrol system consisting of a gas control valve/regulator, a standing pilot burner assembly, a thermopile, a piezo ignitor, and the ON/OFF switch.THIS UNIT DOES NOT REQUIRE 110 VOLT POWER TO OPERATE. All exhaust gases must be vented outside the structure of the living-area.Combustion air is drawn from outside the living-area structure. This appliance may be installed in Manufactured Housing only after the home issite located. May be installed in a bedroom - in Canada install with a listed thermostat, in the USA install per local codes.WARNINGS:Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to the information in theowner’s and installation manual provided with this appliance. For assistance or additional information consult a qualified installer, serviceagency or the gas supplier.Installation and repair should be performed by a qualified service person. The appliance should be inspected before use and at least annuallyby a qualified service person. More frequent cleaning may be required where excessive lint from material like carpeting and bedding is present.The control compartment, the burner compartment and all circulating air passageways of the appliance must be kept clean and clear at alltimes.Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperiesThis appliance must not be connected to a chimney flue servicing a separate solid fuel burning appliance.This room heater is a Direct-Vent Gas-Fired appliance. DO NOT burn wood or other material in this heater.Children and adults should be alerted to the hazards of high surface temperature and should stay away to avoid flesh burns or clothing ignition.Young children should be carefully supervised at all times when they are in the same room as the appliance.CAUTION:All safety screen or guard components removed for servicing, must be replaced prior to operating the appliance.Clothing or other flammable material and liquids with flammable vapors should not be placed on or near the appliance.Risk of electrical shock. Switch the household breaker off or remove fuse before servicing unit.Use Simpson DURA-VENT direct vent system (Model GS) to vent this appliance to the exterior (direct discharge only without duct connection).Minimum Clearances to CombustiblesUnit to Sidewall ................................... 10” Alcove Min. Height....................................... 58”Unit to Backwall .................................. 5” Alcove Max. Depth ....................................... 45”Unit to Cornerwall............................... 5” Alcove Min Width ......................................... 42”Front of Unit ........................................ 36”L.P. N.G. L.P. N.G.Input Rate on “HI” (BTU/Hr)* . . . . . . 31,000 31,000 Minimum Inlet Pressure (inches W.C.) . . . . . . . . 11” 5.5”Input Rate on “LO” (BTU/Hr)* . . . . . 15,500 15,500 Maximum Inlet Pressure (inches W.C.) . . . . . . . . 13” 7”Main Burner Orifice (DMS)* . . . . . . . .0625 #37 Manifold Pressure on “HI” (inches W.C.) . . . . . . 10” 3.5”Output (BTU/Hr) Fan On* . . . . . . . . . 25,575 24,800 Manifold Pressure on “LO” (inches W.C.) . . . . . 2.7” 1”Output (BTU/Hr) Fan Off* . . . . . . . . . 25,265 24,645This room heater is equipped at the factory for use with natural gas. If conversion to propane (LP) fuel is desired theoptional factory conversion kit must be used.Blower Electrical Rating: 115v, 1.5 Amps, 60 Hz FAN TYPE VENTED CIRCULATORManufacture 1998 Jan. Apr. Jul. Oct.Date: 1999 Feb. May Aug. Nov.2000 Mar. Jun. Sep. Dec.10850 117th Pl. N.E. Kirkland, WA 98033IGNTravis Industries 93508102 091002

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!