REV C (10-01-10)INSTALLATION MANUAL – D54. The relationship between the barrel and plunger length must exceed the surface strokecapacity. For example, a <strong>Model</strong> 5 has a 168” surface stroke. The bottom hole pump(BHP) barrel is 240” long. The BHP plunger is 48”. The effective stroke length is 192”.Therefore, the BHP stroke capacity is 24” longer than the surface stroke capacity. SeeFigure 39.For a model 5 pumping unit, the following specifications exist:Specified strokelengthPlunger travel for strokelength (2:1 ratio)Available plungertravel (inches)Plunger margin at fullstroke (inches)168 84 90.5 6.5Figure 39. Barrel to Plunger Length DistanceSECTION 5 – INSTALLATION26