■ Penetrameters and Visibility <strong>of</strong> Discontinuities<br />

It should be remembered that even if a certain hole in a penetrameter is<br />

visible on the radiograph, a cavity <strong>of</strong> the same diameter and thickness may<br />

not be visible. The penetrameter holes, having sharp boundaries, result in an<br />

abrupt, though small, change in metal thickness whereas a natural cavity<br />

having more or less rounded sides causes a gradual change. Therefore, the<br />

image <strong>of</strong> the penetrameter hole is sharper and more easily seen in the<br />

radiograph than is the image <strong>of</strong> the cavity. Similarly, a fine crack may be <strong>of</strong><br />

considerable extent, but if the x-rays or gamma rays pass from source to film<br />

along the thickness <strong>of</strong> the crack, its image on the film may not be visible<br />

because <strong>of</strong> the very gradual transition in photographic density. Thus, a<br />

penetrameter is used to indicate the quality <strong>of</strong> the radiographic technique and<br />

not to measure the size <strong>of</strong> cavity that can be shown. In the case <strong>of</strong> a wire<br />

image quality indicator <strong>of</strong> the DIN type, the visibility <strong>of</strong> a wire <strong>of</strong> a certain<br />

diameter does not assure that a discontinuity <strong>of</strong> the same cross section will<br />

be visible. The human eye perceives much more readily a long boundary than<br />

it does a short one, even if the density difference and the sharpness <strong>of</strong> the<br />

image are the same.<br />

Charlie Chong/ Fion Zhang<br />

<strong>Radiography</strong> in Modern Industry. Rochester, NY: Eastman <strong>Kodak</strong> Co. 1980