■ Maintain an accurate, up-to-date log<br />

containing all information that could affect process control. The following<br />

should be included in the log:<br />

1. Maintenance data and changes resulting from readjustment <strong>of</strong> an<br />

exposing unit, including the supply <strong>of</strong> electrical current to the unit and any<br />

significant changes in line voltage.<br />

2. Maintenance data and changes resulting from readjustment <strong>of</strong> a processor.<br />

3. Age <strong>of</strong> the developer replenisher.<br />

4. Replenishment rate <strong>of</strong> the developer.<br />

5. Age <strong>of</strong> the developer.<br />

6. Temperature <strong>of</strong> the developer at the time control strips are being<br />

processed.<br />

7. Comments on fixer and wash and their replenishment rates. (Although the<br />

condition <strong>of</strong> the fixer and the wash does not noticeably affect the variability<br />

<strong>of</strong> film densities, the condition <strong>of</strong> each does have an effect on the physical<br />

quality <strong>of</strong> processed film.)<br />

Charlie Chong/ Fion Zhang<br />

<strong>Radiography</strong> in Modern Industry. Rochester, NY: Eastman <strong>Kodak</strong> Co. 1980