Control limits for variables <strong>of</strong> the exposing unit and the film processing are<br />

wider than if either were monitored individually. The densitometric data<br />

obtained from the control strips can be utilized in several ways. The table<br />

below shows densitometric readings for a 10-day period. Some <strong>of</strong> the data in<br />

Figure 78 are plotted on one process control chart (See Figure 80) to show<br />

variations in exposure and processing; some are plotted on another process<br />

control chart (See Figure 81) to indicate changes in contrast.<br />

Charlie Chong/ Fion Zhang<br />

<strong>Radiography</strong> in Modern Industry. Rochester, NY: Eastman <strong>Kodak</strong> Co. 1980